ALArm
DEFAULt
rEstorAL
DEFAULt
D8 by CID
D16 by CID
D8/D16 by SMS
ALARM
RESTORAL
ALARM
RESTORAL
ALARM
RESTORAL
Duress
ON
P75E 1E P77E 1E P75E 1E P77E 1E P191E 1E P193E 1E
Medical
ON
P75E 2E P77E 2E P75E 2E P77E 2E P191E 2E P193E 2E
KP Panic & KS Panic
ON
ON
P75E 3E P77E 3E P75E 3E P77E 3E P191E 3E P193E 3E
Fire
ON
P75E 4E P77E 4E P75E 4E P77E 4E P191E 4E P193E 4E
Panel tamper
ON
ON
P75E 5E P77E 5E P75E 5E P77E 5E P191E 5E P193E 5E
External tamper
ON
ON
P75E 6E P77E 6E P75E 6E P77E 6E P191E 6E P193E 6E
Keypad Tamper
ON
ON
P75E 7E P77E 7E P75E 7E P77E 7E P191E 7E P193E 7E
Exit Installer Mode
ON
P75E 8E P77E 8E P75E 8E P77E 8E P191E 8E P193E 8E
Radio Tamper
ON
ON
P92E 1E P93E 1E P75E 9E P77E 9E P191E 9E P193E 9E
Radio Panic
ON
ON
P92E 2E P93E 2E P75E 10E P77E 10E P191E 10E P193E 10E
Radio Battery
ON
P92E 3E P93E 3E P75E 11E P77E 11E P191E 11E P193E 11E
Supervision fail
ON
P92E 4E P93E 4E P75E 12E P77E 12E P191E 12E P193E 12E
Panel battery
ON
ON
P92E 5E P93E 5E P75E 13E P77E 13E P191E 13E P193E 13E
Mains fail
ON
ON
P92E 6E P93E 6E P75E 14E P77E 14E P191E 14E P193E 14E
[not used]
ON
P92E 7E P93E 7E P75E 15E P77E 15E P191E 15E P193E 15E
[not used]
ON
P92E 8E P93E 8E P75E 16E P77E 16E P191E 16E P193E 16E
Option No.
Description
Default
P82E
1E
Send RESTORAL report immediately
OFF
2E
Send RESTORAL after siren time
OFF
3E
Send RESTORAL after Disarm & seal
OFF
4E
Send RESTORAL after Disarm always
ON
P75E, P92E, P191E
P77E, P93E, P193E
rEPort misCELLAnEoUs ALArms
rEPort misCELLAnEoUs rEstorALs
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
See table.
rELAtED oPtions
P82E Restoral Reporting Options
KPX+
PRO TIP
When selecting zones, MEMORy E
selects all, 0 E deselects all.
These options select which Miscellaneous alarms will trigger the dialler to send
Miscellaneous Alarm and Restoral reports to the Central Station or by SMS messaging.
Alarms are sent on activation. Restorals are sent according to P82E settings. Mains Fail
and Low Battery Restorals are sent when the power has been restored.
Note the different program option numbers for the D8 and D16.
KPX+
PxxE [Zone Number] E to enable/disable zones
NAVIGATOR
PxxE or P92E > Select zones
SMS*
P[MasterCode]E P[InstallerCode]E PxxE [Zone Number] E
Or use
NessXCEL
app
xx = See the table for program option numbers
P82E 1E–4E
rEstorAL rEPorting oPtions
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
4E, ON: Always send Restoral on
Disarm.
rELAtED oPtions
P76E Report zone restorals.
This option selects when the dialler sends zone Restoral reports. Only one of the following
options may be selected.
Restoral reporting options also apply to 24hr zones.
KPX+
P82E xE to enable/disable the option
NAVIGATOR
P82E > enable/disable xE
SMS*
P[MasterCode]E P[InstallerCode]E P82E xE
Or use
NessXCEL
app
x = 1E, 2E, 3E or 4E
* SMS programming shows the full SMS string to send. KPX+ and
NAVIGATOR programming assumes the panel is already in program mode.
50
NESS D8XCEL / D16XCEL CONTROL PANEL – INSTALLATION MANUAL REV 1.1
P r o g r A m m i n g