ZONES 1–8
(D8 & D16)
ZONES 9–16
(D16)
Option No. Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
P65E
SUPERVISED ZONES
P65E
sUPErVisED ZonEs
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
all OFF: No Supervision zones.
notEs
If Radio Supervision is enabled, P66E
5E off, then the supervision feature
cannot be used as an inactivity monitor.
rELAtED oPtions
P66E 1E–4E Supervision Alerts.
P66E 5E Wired Zone Supervision.
P67E Zone Supervision Time.
P92E 4E (D8) Report Supervision.
P75E 12E (D16) Report Supervision.
Any zone 1-8 or 1-16 can be a Supervised Zone.
supervision for hArDWirED ZonEs
In operation, a Supervised Zone is subject to the Supervision Time (P67E). If the zone/s
has not sealed or unsealed during the Supervision Time, then the programmed alerts will
turn on (as programmed by P66E 1E-4E, P92E 4E or P75E 12E). Zone Supervision can be
used as an "inactivity monitor" to sound an alert or send a dialler report if a zone has had
no activity during a set period of time. (For example, to monitor an aged person's home).
• A zone which is permanently in a sealed or unsealed state for the duration of Supervision
Time will be treated as a Supervision alarm.
• If P66E 5E is on, Zone Supervision acts on wired zones. If P66E 5E is off,
Zone
Supervision acts on radio zones.
• Each Supervised zone has its own supervision timer.
• Zone Supervision is independent of the armed state of the panel.
• Zone Supervision can be temporarily disabled by Excluding the zone/s.
• The zone which caused the Supervision alarm flashes on the keypad. Entering a valid
code + E will reset Supervision alarms.
supervision for rADio ZonEs
The purpose of Radio Supervision is to verify the correct operation of Ness Radio PIRs. The
Supervision signal from the Radio PIR tells the panel that the device has not been removed
from radio range and is in working order.
A non-SUPERVISION enabled Radio PIR will transmit signals to the panel only when it has
detected an event. Obviously, there is no guaranteed signal period.
In either case, when the allowed time limit is exceeded then a WARNING is first given (if
programmed by P66E 3E), and then after 1 minute, the programmed RADIO SUPERVISION
ALERTS are generated by the panel.
P66E 5E must be off for supervision to work on radio zones.
KPX+
P65E [Zone Number] E to enable/disable zones
NAVIGATOR
P65E > Select zones
SMS*
P[MasterCode]E P[InstallerCode]E P65E [Zone Number] E
Or use
NessXCEL
app
* SMS programming shows the full SMS string to send. KPX+ and
NAVIGATOR programming assumes the panel is already in program mode.
rADio sUPErVision oPErAtion
The purpose of Radio Supervision is to verify the correct operation of Ness Radio PIRs. The Supervision signal from the
Radio PIR tells the panel that the device has not been removed from radio range and is in working order.
A non-SUPERVISION enabled Radio PIR will transmit signals to the panel only when it has detected an event. Obviously,
there is no guaranteed signal period.
In either case, when the allowed time limit is exceeded then a WARNING is first given (if programmed by P66E 3E), and
then after 1 minute, the programmed RADIO SUPERVISION ALERTS are generated by the panel.
KPX+
PRO TIP
When selecting zones,
mEmory E
selects all
zones,
0 E
deselects all
zones
39
NESS D8XCEL / D16XCEL CONTROL PANEL – INSTALLATION MANUAL REV 1.1
P r o g r A m m i n g