CONNECTION DIAGRAMS
nEss D8/D16
ControL PAnEL
ExtErnAL
intErnAL
TAMP
C
STR
RESET
SIREN
RE
D
RE
D
BLAC
K
BLAC
K
N.O. Tamper SWITCH
(761-002) Colour: BLaCK
STrOBe LIGHT
(NOI300)
The terminal block should
be mounted inside the
siren cover.
HOrN
SpeaKer
(NOI110)
2K2
9
NESS D8XCEL / D16XCEL CONTROL PANEL – INSTALLATION MANUAL REV 1.1
Optional Accessories for D8 & D16
Generic Detector Wiring Examples
LUX HW Detector Wiring
Siren Wiring Examples
+12V
Re
d
DA
TA
White
RS
SI
Blue
OV
Black
100-200
ness radio interface
.
Blu
Brn
Grn
Wht
Red
Blk
1
2
3
106-012
Weigand interface
.
Provides connection for up to 3
addressable Weigand Readers
(Ness 101-014).
See Access Control options,
pages 81-86.
READER
#
header
RECEIVER
header
The Relay Board and the Output Expander Board connect to
the Aux header but not at the same time.
External trigger to turn on the LUX
nightlight.
Pull to 0v to turn on.
1
Nightlight status output. Pulls low
(0v) when light is on.
Fast reacting output is low (0v)
when movement is detected.
Addi12V terminal.
0V
+12V
AU
X4
AU
X3
AU
X2
AU
X1
NO
C
AU
X1
NC
NO
C
AU
X2
NC
NO
C
AU
X3
NC
NO
C
AU
X4
NC
106-013
relay board
.
Provides 4 relay
outputs suitable for
switching low voltage
accessories.
100-699
output Expander
.
Provides 16 programmable
open collector outputs.
See page 59.
AUX header
AUX header
K-6002D
internet interface kit
.
Provides internet
connectivity for use with
third party apps such as
iComms & aComms.
XCEL Serial
header (4 pin)
450-246
Serial cable
LAN
D8/D16 PAnEL
D8/D16 PAnEL
4 wire example
6 wire example
with 24hr Tamper
See P30E~P36E Zone Vibration Sensitivity, page 26
Vibration Sensor
D8/D16 PAnEL
D8/D16 PAnEL
Any nEss or gEnEriC
hArDWirED DEtECtor
nEss LUx hW
DEtECtor
DEtECtor
nEssEnsor
0V
aLarm
Tamper
N.C.
N.C.
+12V
N.C.
N.C.
Zone
Zone
TAMP
0V
C
C
C
+12V
2K
2
Zone
Zone
0V
C
C
+12V
2K2
0V
aLarm
Tamper
N.C.
N.C.
+12V
N.C.
N.C.
Zone
Zone
TAMP
0V
C
C
C
+12V
2K2
2K2
Zone
Zone
C
C
2K2
+12V
Tamper
aL
arm
0V
+
12
V
OUT
Fa
ST
Se
NS
LIGHT
OUT
IN
AUX1
AUX2
AUX3
AUX4
+12V
0V
EXAMPLE
Using Aux1 on your D8/D16 to turn on
the the LUX HW nightlight from the
keypad or even remotely.
INSTALLER PROGRAMMING
P141E 4E should be ON.
OPERATION
• LCD keypad, press 11* or 11# to turn
on/off
• Navigator keypad, Aux Control menu.
• SMS, send [usercode]E11ON to turn on
or [usercode]E11OFF to turn off
1
HINT. Use a 450-159 loom (cut and use one end
only into the panel's Aux header).
Or a 100-699 or 106-011 output expander or
106-013 relay board can be used and wired
accordingly.
101-244
IP232
Ethernet
Module