background image

The 

CELL

 icon indicates various cellular 

conditions.

1. 

CELL

 with flashing signal strength 

 

indicates the dialler is in use.
2. 

 with flashing 

CELL

 indicates a cellular 

dialler fault. 
3. 

CELL

 with flashing 

 indicates 'no SIM' 

Card is fitted.

11

NESS D8XCEL / D16XCEL CONTROL PANEL – INSTALLATION MANUAL REV 1.1

kPx+ LCD kEyPAD

sAtUrn LCD kEyPAD

Fire Alarm

Press and hold the two 

FirE

 (1 & 3) keys 

together for FIRE alarm.

See P126E 2E to enable keys. See P75E 4E, 

P191E 4E to enable fire alarm reporting.

Medical Alarm

Press the two Medical (4 & 6) keys together 

for Medical alarm.

See P126E 3E to enable keys. See P75E 2E, 

P191E 2E to enable medical alarm reporting.

Keypad Tamper Alarm

Applies to all keypads and is designed to 
prevent multiple attempts to guess a user 
code either at the keypad or by SMS. 

A Keypad Tamper alarm is generated by 5 
failed attempts to arm, disarm or any other 
command that requires entry of a user code.

Keypad Tamper Alarm sounds the Siren, 
Strobe and Reset outputs. A Keypad Tamper 
report is sent by CID or SMS if programmed 
by P75E, P191E.

Clear the alarm by entering a valid user code 
+ E

All the key functions described above 
also apply to Saturn keypads.

Panic Alarm

Press and hold the two emergency keys 

together for PANIC alarm.

See P126E 1E to enable. See P75E 3E, 

P191E 3E to enable panic alarm reporting

Press and hold the 

P

 key. Release 

when the desired volume is 
reached. 
The volume level is displayed on 
the LCD during adjustment.

Adjust Key Beep Volume

Press and hold the 

0

 key. 

Release when the desired 
volume is reached. 
The volume level is displayed 
on the LCD during adjustment.

To display all available 
LCD icons press and hold 
the 

E

 key. 

Display Test can be used 
in any mode.

Adjust Chime Volume

Display Test

Press and hold the 

9

 key to 

adjust the brightness of the 
LCD backlight. Release when 
the desired brightness is 
reached. 

Adjust LCD Backlight

10 Levels

note.

 Beep/Chime Volume and LCD Brightness 

settings are stored in the keypad. Adjust each 
keypad individually. Defaults to loudest/highest 
settings on power down.

Note that some Saturn keypad models do not 
have CELLULAR signal and real time clock 
display. Operational functions are unaffected, 
however it's recommended that at least one 
KPX+ keypad be installed to provide cellular 
signal indication.

Summary of Contents for D16XCEL

Page 1: ...ons Cellular Dialler Onboard Access Control onboard Powerful Wireless Options C BUS Compatible using Ness MiniCentral Multiple Arming Modes Area Partitioning Dual Voltage 17VAC 20VDC 8 or 16 Hardwired or Wireless zones Easy Programming via Keypad Fast Programming via PC Free NessComms Installer Software Convenient Programming via SMS Adjustable Vibration Inputs on all Zones 8 16 Operation by Smart...

Page 2: ...resence of in band radio signals high power transmissions or interference caused by electrical appliances such as Mains Inverters Wireless Routers Cordless Phones Computers TVs and other electronic devices may reduce radio range performance While such occurrences are unusual they are possible In this case it may be necessary to either increase the physical separation between the Ness receiver and ...

Page 3: ...9 Report Miscellaneous alarms 50 Report Miscellaneous Restorals 50 Test Call options 51 Dialler format options 52 53 Enable SMS Reporting 53 Area1 Area2 open close reports 54 Siren Chirp Flash options 54 Other reports 55 Enable Test Calls 56 Mains Report Delay 56 Swinger Shutdown 56 Line Fault Monitor 56 No Memory Warning zones 57 Factory Defaults Clear Radio Devices 58 Clear Memory 58 Clear Panel...

Page 4: ...rammable Reset Output lockout 30 event memory from KPX and Saturn keypads 80 event memory can be accessed using Navigator keypad or NessComms Standard defaults to suit most applications Easy programming by keypad or NessComms software New modem chip allows common modems to be used for upload download in 300baud mode All programming data is permanently stored in a non volatile memory All inputs and...

Page 5: ...8x D16x V7 3 or later MiniCENTRAL To Clipsal C Bus Free Software Optional Product Direct Connect On Site D8x D16x Deluxe SERIAL 450 246 Serial cable 101 231 Serial to USB Adapter cable Note D8x D16x and XCEL models v8 and later use 450 246 serial cable 4 pin Previous versions of D8x D16x use 450 185 RS232 cable 3 pin Ness XCEL APP iOS and Android app NessXCEL app for iPhone or Android devices prov...

Page 6: ...abling needed for the installation 4 Insert the red PCB stand offs in the housing and then plug the circuit board onto the stand offs See the ESD Warning on this page 5 Wire the sensors sirens and accessories to the main board terminal blocks as per the wiring instructions in this installation manual 6 Connect the 3G antenna connector on the PCB and install the antenna outside the panel housing in...

Page 7: ...time P29E or whenever the panel is reset whichever comes first This output is protected by an Automatic Reset fuse STR A latched 12VDC output for connecting strobe lights This output will reset after 72 hours 3 days or when the panel is disarmed D8 D16 versions prior to V4 5 allow indefinite strobe operation until the panel is reset A maximum of 2 x 1 Watt Strobes Ness Part No NOI300 can be connec...

Page 8: ...for Ness PD Portable Download tool RED RED READER SERIAL 0V F6 AUX1 AUX2 AUX3 AUX4 12V NESS RADIO RECEIVER USB Future Use SIM 3G SIREN F1 F1 F7 F2 F2 F3 RESET 12V 12V 0V Z9 Z10 Z12 Z14 Z11 Z13 Z15 Z16 C C C C 0V Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 TAMP N O TAMPER SWITCH 761 002 Colour BLACK Supplied with Ness siren covers 12VDC Output END OF LINE RESISTORS The default end of line resistor value is 2k2 2200 Oh...

Page 9: ...able for switching low voltage accessories 100 699 Output Expander Provides 16 programmable open collector outputs See page 59 AUX header AUX header K 6002D Internet interface kit Provides internet connectivity for use with third party apps such as iComms aComms XCEL Serial header 4 pin 450 246 Serial cable LAN D8 D16 panel D8 D16 panel 4 wire example 6 wire example with 24hr Tamper See P30E P36E ...

Page 10: ...Zone is sealed Zone is unsealed Zone is in alarm Zone s are unsealed OR Power fault OR Panel is armed Ready to Arm Panel is disarmed or Area 1 is disarmed if using Areas Panel is armed or Area 1 is armed if using Areas Area 2 is disarmed Area 2 is armed if using Areas Home Mode is disarmed Panel is armed in Home Mode Day Mode enabled see page 29 Normal Memory mode selected New alarm s in memory No...

Page 11: ... P75E P191E Clear the alarm by entering a valid user code E All the key functions described above also apply to Saturn keypads Panic Alarm Press and hold the two emergency keys together for PANIC alarm See P126E 1E to enable See P75E 3E P191E 3E to enable panic alarm reporting Press and hold the P key Release when the desired volume is reached The volume level is displayed on the LCD during adjust...

Page 12: ... 11 Touch to display the information screens 12 Cellular signal strength display Zone names can be customised by SMS The Zone List display will show 8 zones for D8XCEL and 16 zones for D16XCEL Zone numbers and descriptions Unsealed zones show a red indicator Touch to close the window The Zone Status Bar displays the zone numbers of unsealed zones If only one zone is unsealed its description will a...

Page 13: ...arm sounds the siren using the FIRE siren sound and sends a fire report if programmed The MEDICAL alarm triggers the strobe light if programmed and sends a medical report if programmed Related options for Fire and Medical P75E P77E P191E P193E P161E P126E 2E 3E P69E 1E Keypad Duress Keypad Duress allows the user to send a silent duress report while disarming if the system is being monitored by a c...

Page 14: ... alarm2 Triggers the Medical Alarm if enabled D123E D123E ACK PANIC alarm3 Triggers the Panic Alarm if enabled S123E S123E ACK Turn ON AUX 1 Turn OFF AUX 1 Turn ON AUX 2 Turn OFF AUX 2 Same procedure for all eight Aux outputs 123E11ON 123E11OFF 123E22ON 123E22OFF 123E ACK 11 ACK 123E ACK 11 ACK 123E ACK 22 ACK 123E ACK 22 ACK 1 The FIRE alarm sounds the siren using the FIRE siren sound and sends a...

Page 15: ...med in this mode 2 Press P InstallerCode E This is Installer Program Mode PROG icon is FLASHING All program options can be programmed in this mode How to EXIT Program Mode Press P E Exits directly to Operating Mode PROG icon is OFF Factory Defaults Master Code 123 Installer Code 000000 15 Ness D8xCEL D16xCEL Control Panel Installation Manual Rev 1 1 p r o g r a m m i n g Special Function Program M...

Page 16: ...ile phone number will receive alarm reports if enabled Up to 10 mobile numbers can be programmed see P180E to P189E See P190E to P194E to enable disable various SMS alarm reports 7 P E To exit program mode PROG icon will turn off Quick start 3 Central Station Monitoring Step KPX or Saturn KP Description Comment 1 P 1 2 3 E Enters User Program Mode PROG icon will turn on Default User Code is 123 2 ...

Page 17: ...mand requires both the master Code and Installer Code to be included M123E ACK M000000E ACK M206E ACK 3456E ACK 3456E ACK M26E ACK 20E ACK M28E ACK 50E ACK M29E ACK 3E ACK M41E ACK 2E ACK ME ACK SMS Programming Commands Programming by SMS SMS commands are extremely flexible in their format Multiple Commands You can send multiple programming commands in one text message in fact the message can be a...

Page 18: ...01 4zz k Radio Sensor Tamper ssss 18 q 383 01 2zz k Radio Sensor Low Battery ssss 18 q 384 01 3zz k Mains Fail ssss 18 q 301 01 050 k Panel Battery Fail ssss 18 q 309 01 051 k Open Disarm ssss 18 1 402 aa 0dd k Force Open Cancel ssss 18 1 406 aa 0dd k Close Arm ssss 18 3 402 aa 0dd k Closing Extended ssss 18 3 464 aa 0dd k Test Report ssss 18 1 602 01 063 k Zone 1 16 Manual Exclude ssss 18 q 573 a...

Page 19: ... zone number See page 21 AREA 1 Identifies the zone as belonging to Area 1 Tue 7 Aug 2018 4 07 22pm Time and date of the event 1 1 Means message 1 of 1 Long SMS messages are split into multiple messages of 160 characters each SMS Monitoring Example 2 Area 1 was Armed by User 1 NESS security report from MYPANEL ARMED USER 1 AREA 1 Tue 7 Aug 2018 4 57 54pm 1 1 Arm disarm reports by SMS can be enable...

Page 20: ...ed switch unsealed Zone Detector Low Battery Wireless PIRs ZB LIST Zones 1 16 wireless PIR low battery Zone Detector Tamper Wireless PIRs ZT LIST Zones 1 16 wireless device tamper alarm Miscellaneous Alarms MISC List one or more miscellaneous alarm Duress Panel Tamper Panic Keypad Tamper Medical Pendant Panic Fire Panel Battery Low Instal End Mains Fail Ext Tamper Status of armed conditions ARM Li...

Page 21: ...t to the panel SMS REPLY T123E LOCATION MYHOME ZONE 2 Z2 RUMPUS text report changes made LOCATION MYHOME ZONE 2 Z2 RUMPUS 1 1 The panel will now be identified in SMS reports as MYHOME and zone 2 as Z2 RUMPUS Using the same method every word and phrase in the SMS message can be renamed Refer to the text table on the following page Deleting a word Text output words can be also be deleted and therefo...

Page 22: ...ME 2 INSTALLER TEL NO 1 INSTALLER TEL NO 2 INTERNAL KEYPAD KEYPAD DISPLAY ENABLE KEYSWITCH LOCATION MAIN 12V MAIN UNIT MANUAL EXCLUDE MANUAL INCLUDE MEDICAL NAK NESS NO AREA NORMAL OUTPUT OFF OUTPUT ON PANIC PENDANT POWER POWER FAILURE POWER NORMAL RADIO DETECTOR REAL TIME CLOCK REPORT FAILURE REPORT NORMAL RESET SEALED SECURITY REPORT SECURITY SYSTEM SHORT ARM SIREN SOFT MONITOR SOFT SIREN SONALE...

Page 23: ...ey in place of the code Example To delete User Code 2 press P202E MEMORY E A keypad code only needs to be deleted if you re not replacing it with a new code Note that User Code 1 Master Code cannot be deleted but can be reprogrammed Arm Only Codes Arm Only is an extra option for user codes See next page for further information User Codes 2 56 can optionally be programmed as Arm Only Codes which ca...

Page 24: ...hey can be disarmed If in Home mode the action is to exit Home mode Codes selected for Code Only Arming and not assigned to any areas are automatically REX codes See page 86 5E Radio Code Enables selected user codes as Radio Codes for operation by Ness Radio Key or Radio Keypad Page 79 how to program Radio Codes 6E Reader Code 1 Enables user codes as Access Control codes assigned to Reader 1 Page ...

Page 25: ...nds delay KPX P27E New Time E Navigator Entry Exit Delay Entry Delay Time 2 Enter new time E SMS P MasterCode E P27E NewTime E Or use NessXCEL app P28E EXIT Delay Time Program Mode Level User Installer Factory Default 60 seconds Notes Programmable from 1 99 seconds RELATED OPTIONS P62E 8E Exit Time x10 Exit Delay Time is the time given to secure and depart the premises after the panel is armed All...

Page 26: ...uired zone s at P30E Each zone has individually adjustable sensitivity for connection of Nessensor Vibration Sensors Zone sensitivity is adjusted by toggling zones ON in options P30E to P36E P30E is Normal Sensitivity vibration analyser disabled This is used for normal alarm devices Zone response time 200ms P31 36E are the options for the 6 levels of vibration sensitivities P31E is the most sensit...

Page 27: ...nstaller Factory Default 1E ON Zone 1 has Entry Delay1 Notes When a zone is selected for this type it is automatically deselected from any other zone type in the DELAY GROUP RELATED OPTIONS P60E 1E Entry Beeps P40E P42E P43E Entry Delay1 zones operate only in the Armed state When Armed at the expiry of exit time these zones will activate the Entry Delay Timer1 P26E when they are triggered If the p...

Page 28: ...PTIONS P60E 4E Tamper Reset Lockout P78E Multiple alarm reports All zones and tamper input can be programmed to Lockout i e cause the RESET OUTPUT to sound only once while the panel is armed The RESET OUTPUT is then locked out for that alarmed zone until entering a valid code has reset the panel If using area partitioning disarming either partition resets the zone lockout for both partitions KPX P...

Page 29: ...sealed zone KPX CHIME The KPX keypad has a special two tone chime which can be enabled in place of the default beep warning tone See P126E 4E Aux 2 Option When the Temporary Day Zone feature is enabled the installer option P63E 6E selects Aux 2 output instead of the strobe output This allows a remote warning device such as a buzzer to be connected for day zone warning This may be needed if an addi...

Page 30: ...s of the mode of panel operation i e Armed Disarmed or Home Monitor When alarmed these zones will activate assigned outputs immediately To reset those alarms a valid user code must be entered Selecting a zone as 24hr will override any other zone type setting such as Instant Delayed or Handover 24hr zones are independent of Area operation All other zone types must be assigned to at least one Area t...

Page 31: ... to enable disable zones Navigator P54E Select zones SMS P MasterCode E P InstallerCode E P54E Zone Number E Or use NessXCEL app P55E Strobe output Zones Program Mode Level Installer Factory Default All ON All zones trigger Strobe output Selects the zones to trigger the Strobe output KPX P55E Zone Number E to enable disable zones Navigator P55E Select zones SMS P MasterCode E P InstallerCode E P55...

Page 32: ...AUX2 4 output Zones Program Mode Level Installer Factory Default All OFF No zones trigger AUX 2 or 4 RELATED OPTIONS P121E P123E Day zone output mapping Selects the zones to trigger the AUX2 or AUX4 outputs This option selects which zones trigger AUX2 or 4 Use P122E 1E and or P124E 1E to enable the ouput Once turned on by a zone alarm the output will remain on until the panel is reset disarmed KPX...

Page 33: ...ea2 P129E EOL Resistor value An externally fitted normally open momentary Keyswitch can be used to Arm Disarm or arm the Home mode The keyswitch is wired to zone 8 zone 8 is then no longer available as a normal alarm input but is still available for use as a Radio Zone 2E 3E OFF No keyswitch operation Zone 8 is a normal alarm input 2E ON Keyswitch cycles between Home and Disarm 3E ON Keyswitch cyc...

Page 34: ...tallerCode E P60E 6E Or use NessXCEL app P60E 7E Disable Keypad display Program Mode Level Installer Factory Default OFF Display is always ON NOTES LCD KEYPADS The LCD display and display backlighting will turn off but the key backlighting will remain on The keypad flap can be closed to reduce stray light from the keys NAVIGATOR KEYPAD The touch screen display will go blank Touch to restore Keypad...

Page 35: ...r P61E enable disable 1E 4E as required SMS P MasterCode E P InstallerCode E P61E 1E 4E as required Or use NessXCEL app P61E 5E 8E Keypad Panic alarm output mapping Program Mode Level Installer Factory Default 5E 8E ON Panic alarm triggers all outputs Notes A Keypad Panic Alarm can be caused by the PANIC keys on the keypad E or together depending on Option P126E1E This option selects which outputs...

Page 36: ...ic without shortcut EMERGENCY PANIC User Code E KPX Keypad Panic with shortcut E NAVIGATOR Keypad Panic with shortcut EMERGENCY PANIC P62E 7E Siren burst on Auto Exclude Program Mode Level Installer Factory Default ON Siren burst on Auto Exclude enabled RELATED OPTIONS P60E 6E Auto Exclude zones This option allows the disabling of the 2 second siren burst at the end of Exit Time which indicates a ...

Page 37: ...E P59E page 31 This option selects which outputs are triggered by alarms in Day Mode 5E ON Day Mode to Reset output 6E ON Day Mode to Strobe output If Brief Day Alarm is enabled P64E 2E then this option sends day alarms to the AUX2 output 7E ON Day Mode to Keypad Sonalert output 8E ON Day Mode to Siren output KPX P63E enable disable 5E 8E as required Navigator P63E enable disable 5E 8E as required...

Page 38: ...aller Factory Default OFF No siren chirps RELATED OPTIONS P68E 8E Quiet Chirps P69E 5E Home Arm by Radio Key P120E 2E Home Arm chirps P120E 3E Radio Key AUX button arms Home Mode If this option is selected the Siren output will Chirp when the panel is armed and disarmed with the Keyswitch input prox cards or Radio Keys This option applies to siren chirps the strobe output always flashes when armin...

Page 39: ...upervision alarms Supervision for RADIO ZONES The purpose of Radio Supervision is to verify the correct operation of Ness Radio PIRs The Supervision signal from the Radio PIR tells the panel that the device has not been removed from radio range and is in working order A non SUPERVISion enabled Radio PIR will transmit signals to the panel only when it has detected an event Obviously there is no gua...

Page 40: ...ode E P InstallerCode E P66E 2E Or use NessXCEL app P66E 3E Zone Supervision alerts Keypad SONALERT Program Mode Level Installer Factory Default OFF Supervision Keypad Sonalert disabled Notes When this option is turned ON it delays the operation of all other selected Supervision outputs by one minute RELATED OPTIONS P65E Supervised Zones Setting this option turns the Keypad Sonalert ON when a SUPE...

Page 41: ...o speed up the Supervision Time by 10 For instance if P67E is set to 1 hour 60 minutes then this option will reduce it to 6 minutes i e 60 divided by 10 KPX P66E 8E to enable disable the option Navigator P66E enable disable 8E SMS P MasterCode E P InstallerCode E P66E 8E Or use NessXCEL app NOTE If P66E 7E and 8E are both ON then the Supervision time is sped up by 60 For instance if P67E is set to...

Page 42: ...For example say P26E is 30sec if you disarm the panel and do not enter the premises then the panel will Auto Re arm in 30 seconds When this option is enabled Auto Re Arm checks that you have entered the premises after disarming After disarming the panel will wait for the duration set for Entry Delay If all zones remain sealed the panel will re arm This is most useful when used with radio keys wher...

Page 43: ...68E 6E Or use NessXCEL app P68E 7E Single Shot Strobe on Arming Program Mode Level Installer Factory Default OFF Strobe Flash on very ARM signal This option provides a choice of operation for the strobe flash when arming by a Radio Key When this option is OFF the strobe will flash every time an ARM signal is received from a valid Radio Key If the panel is armed any subsequent ARM signals will flas...

Page 44: ...ffect the RESET output This option selects the Quiet Siren sound in Home Mode The Quiet Siren sound is a continuous beep beep beep sound rather than the normal siren sound KPX P69E 3E to enable disable the option Navigator P69E enable disable 3E SMS P MasterCode E P InstallerCode E P69E 3E Or use NessXCEL app P69E 4E 6 Beeps on Arming Program Mode Level Installer Factory Default OFF Keypad gives 3...

Page 45: ... Is not saved to MEMORY and the MEMORY display does not flash KPX P69E 6E to enable disable the option Navigator P69E enable disable 6E SMS P MasterCode E P InstallerCode E P69E 6E Or use NessXCEL app P69E 7E Beeps During Exit Delay Fully Armed Mode Program Mode Level Installer Factory Default Exit Beeps OFF RELATED OPTIONS P28E Exit Delay Time When set ON this option gives an audible warning duri...

Page 46: ...ng KPX Keypad Dialler client codes can be entered in Hexadecimal as required by some central stations Use the following keys to enter the hex digits B C D E or F HEX DIGIT KPX Key displayED AS B Key 11 C ARM Key 12 D HOME Key 13 E EXCLUDE Key 14 F MEMORY key 15 HEX Account Numbers Using NAVIGATOR Keypad Navigator keypad provides buttons for entering Hex digits B C D E F in the P72E option P70E P71...

Page 47: ...e NessXCEL app To delete a telephone number enter the MEMORY key in place of the telephone number Example to delete CID Telephone Number 2 press P171E MEMORY E P172E phone number For CID TEST CALLS RELATED OPTIONS P87E 1E Alternate Primary Secondary telephone numbers P86E 1E Disable dialler P86E 2E Enable Contact ID reporting P89E 1E Enable Test Calls The phone number for Contact ID TEST reports t...

Page 48: ...SMS P191E Report misc alarms by SMS P192E Report zone restores by SMS P193E Report misc restores by SMS P194E Report Open Close by SMS NOTES If no mobile phone numbers are programmed then SMS reporting is disabled however acknowledgement ACK texts are sent in reply to an SMS command eg If you arm the panel by SMS you will receive an ACK reply even if no numbers are programmed here If P86E 1E Disab...

Page 49: ...nd a Restoral KPX PxxE Zone Number E to enable disable zones Navigator PxxE Select zones SMS P MasterCode E P InstallerCode E PxxE Zone Number E Or use NessXCEL app P78E Report Multiple zone alarms Program Mode Level Installer Factory Default No zones report Multiple Alarms Notes Only zones that have previously sent an Alarm will send a Restoral RELATED OPTIONS P89E 4E Swinger shutdown Zones selec...

Page 50: ...TORAL after Disarm always ON P75E P92E P191E P77E P93E P193E Report Miscellaneous alarms Report Miscellaneous RESTORALS Program Mode Level Installer Factory Default See table Related Options P82E Restoral Reporting Options KPX PRO TIP When selecting zones MEMORY E selects all 0 E deselects all These options select which Miscellaneous alarms will trigger the dialler to send Miscellaneous Alarm and ...

Page 51: ...D OPTIONS P89E 1E Enable Test Calls P83E Test Call interval Installer s TIP Use P88888888E prior to powering down for a short time This will save the current Time Before Next Test Call and the Real Time Clock into permanent memory On power up these times will be restored This option sets the time before the next test call and is used to set the preferred time for Test Calls Programmable from 2 to ...

Page 52: ...eports will be sent and the dialler will ignore incoming SMS messages Turn this option on if you are using the panel as a local system without an active SIM card Leaving the dialler enabled without a SIM will generate unwanted dialler errors KPX P86E 1E to enable disable the option Navigator P86E enable disable 1E SMS P MasterCode E P InstallerCode E P86E 1E Or use NessXCEL app P86E 2E Enable repo...

Page 53: ...ng Attempts Program Mode Level Installer Factory Default ON 4 dialling attempts Notes Sets the total number of dialling attempts E g If 4 dialling attempts is selected this means 2 attempts per telephone number RELATED OPTIONS P87E 1E Split Dial Sets the number of dialling attempts when sending reports to a Central Station OFF sets a maximum 10 dial attempts before a 5 minute sleep and 10 more re ...

Page 54: ...E Flash Strobe on kiss off Enables a two second Siren burst on a successful Closing report This is used to give audible indication that the dialler has successfully sent the Arming report to the central station KPX P88E 3E to enable disable the option Navigator P88E enable disable 3E SMS P MasterCode E P InstallerCode E P88E 3E Or use NessXCEL app P88E 4E Strobe Flash on kiss off Program Mode Leve...

Page 55: ...iately on arming KPX P88E 6E to enable disable the option Navigator P88E enable disable 6E SMS P MasterCode E P InstallerCode E P88E 6E Or use NessXCEL app P88E 7E Manual Exclude Report Program Mode Level Installer Factory Default ON Manual Exclude Reports enabled RELATED OPTIONS P88E 8E Auto Exclude Reports Enables Manual Exclude Reports for zones Exclude Reports for 24hr zones are sent on exitin...

Page 56: ...eing sent to the Central Station in the event of brief power failures KPX P89E 2E to enable disable the option Navigator P89E enable disable 2E SMS P MasterCode E P InstallerCode E P89E 2E Or use NessXCEL app P89E 4E Swinger Shutdown Program Mode Level Installer Factory Default ON Swinger Shutdown enabled Notes This prevents unnecessary multiple alarms reported to the Central station in cases for ...

Page 57: ...nitor Program Mode Level Installer Factory Default OFF No Line Fault Monitor RELATED OPTIONS P122E 5E Line Fault to AUX2 When this option is enabled the keypad s will display cellular signal errors If the cellular signal is low or absent KPX keypad will flash CELL 00 Navigator displays Line Fault KPX P89E 5E to enable disable the option Navigator P89E enable disable 5E SMS P MasterCode E P Install...

Page 58: ...de Level Installer Factory Default not applicable Notes Note this option will also delete Radio Devices programmed on zones This option restores all panel program options to their factory default values Defaults all program options except User Codes and Radio Codes Note this option will also delete Radio Devices programmed on zones KPX P97E to restore factory defaults Navigator P97E to restore fac...

Page 59: ...put off Note that the USER CODE does not have to be assigned to an AREA for this to work If P117E 6E is ON then the ARM DISARM buttons on Radio Keys do not change the Code13 15 outputs on the output expander Only the AUX button works pulsing ON the Code13 15 output for the time set by P145E Use this option along with option P117E 5E to configure the output expander outputs as per the output tables...

Page 60: ...nder Zones P119E Output Expander Alarm Zones P118E Output Expander Zones Program Mode level Installer Factory Default All OFF No Output Expander zones Notes Selecting a zone in both P118 P119 options effectively gives pulsed outputs whenever that zone alarms Select zones that will be output whenever the zone is unsealed When the zone reseals the output automatically goes off Additionally if a zone...

Page 61: ...ble 2E SMS P MasterCode E P InstallerCode E P120E 2E Or use NessXCEL app P120E 3E Radio Aux button arms Home mode Program Mode level Installer Factory Default OFF Note This option also enables Radio Key Home Arming chirps regardless of the state of P64E 4E Radio Key siren chirps RELATED OPTIONS P69E 5E Radio key Home arm by ON OFF buttons This option enables the AUX button on a Ness RK4 Radio Key ...

Page 62: ...sequence once when the zone is triggered and again at the end of entry delay If Entry Beeps are disabled P60E 1E Smart Beeps will only be heard at the end of entry delay Smart Beeps use the keypad s onboard sonalert so option P63E 3E and or 7E must be on to enable the sonalert output for Home alarms and Day alarms KPX P120E 6E to enable disable the option Navigator P120E enable disable 6E SMS P Ma...

Page 63: ...et P121E 2E Zone Supervision Alarms to Aux1 RELATED OPTIONS P65E P66E P67E Radio Supervision With this option ON the AUX1 output will turn on when a SUPERVISED RADIO alarm is triggered The Aux1 output turns off when the panel is disarmed reset P121E 3E Enable AUX1 for AutoTimer Radio Key Panic Toggles AUX1 Notes When this option is on Radio Key Panic buttons will no longer sound alarms or report a...

Page 64: ...tton AUX1 is turned OFF with the keypress 11 Right hand STAR button P141E 8E Pulse AUX1 RELATED OPTIONS P145E AUX1 Pulse Time P141E 4E must also be ON for this option to work This option converts the P121E 1E and the P141E 1E 2E 3E 4E 5E options into a pulsed AUX1 output AUX1 is pulsed on for the time set in P145E Option No Description Default Note P145E AUX1 timer 20 sec 1 to 99 seconds AUX1 outp...

Page 65: ...sterCode E P InstallerCode E P122E 1E 8E as required Or use NessXCEL app P122E 1E Zone Alarms to Aux2 RELATED OPTIONS P59E Aux2 zones With this option ON zones selected in P59E will turn on Aux2 when they go into alarm The Aux2 output turns off when the panel is disarmed reset P122E 2E Zone Supervision Alarms to Aux2 RELATED OPTIONS P65E P66E P67E Radio Supervision Setting this option turns the AU...

Page 66: ...ypress 22 Left hand STAR button AUX2 is turned OFF with the keypress 22 Right hand STAR button P142E 8E Pulse AUX2 RELATED OPTIONS P146E AUX2 Pulse Time P142E 4E must also be ON for this option to work This option converts the P122E 1E and the P142E 1E 2E 3E 4E 5E options into a pulsed AUX2 output AUX2 is pulsed on for the time set in P146E Option No Description Default Note P146E AUX2 timer 20 se...

Page 67: ...e option as required Navigator P123E enable disable 1E 8E as required SMS P MasterCode E P InstallerCode E P123E 1E 8E as required Or use NessXCEL app P123E 1E Zone Alarms to Aux3 RELATED OPTIONS P58E Aux1 3 zones P121E 1E Zone Alarms to AUX1 With this option ON zones selected in P58E will turn on Aux3 when they go into alarm The Aux3 output turns off when the panel is disarmed reset P123E 3E Enab...

Page 68: ...3 Applies to KPX Keypad and Saturn Keypad When this option is on AUX3 is turned ON or PULSED with the keypress 33 Left hand STAR button AUX3 is turned OFF with the keypress 33 Right hand STAR button P143E 8E Pulse AUX3 RELATED OPTIONS P147E AUX3 Pulse Time P143E 4E must also be ON for this option to work This option converts the P143E 1E 2E 3E 4E 5E options into a pulsed AUX3 output AUX3 is pulsed...

Page 69: ... including keypress beeps This is useful in cases where for example entry beeps or other keypad beeps need to be heard in more than one location on the premises Adding an additional keypad would also achieve the same result P124E 3E Enable AUX4 for AutoTimer RELATED OPTIONS P370E to P389E AutoTimers When this option is on AUX4 is enabled for use by AutoTimer P124E 4E Radio Key Panic Pulses AUX4 RE...

Page 70: ...tton AUX4 is turned OFF with the keypress 44 Right hand STAR button P144E 8E Pulse AUX4 RELATED OPTIONS P148E AUX4 Pulse Time P144E 4E must also be ON for this option to work This option converts the P144E 1E 2E 3E 4E 5E options into a pulsed AUX4 output AUX4 is pulsed on for the time set in P148E Option No Description Default Note P148E AUX4 timer 20 sec 1 to 99 seconds P148E AUX4 timer Program M...

Page 71: ...ctory Default OFF RELATED OPTIONS P318E P328E P338E P319E P329E P339E This option enables an access control reader to pulse AUX5 when a valid access card is presented Set the reader using P318E P328E or P338E P151E 8E PULSE AUX5 RELATED OPTIONS P318E P328E P338E P319E P329E P339E This option sets AUX5 to Pulse momentary output for any action that triggers AUX5 inckuding keypad operation see P151E ...

Page 72: ...ct volume from 1 lowest to 99 highest KPX P162E New Value E Navigator P162E New Value E SMS P MasterCode E P InstallerCode E P162E NewValue E Or use NessXCEL app Zones 1 8 D8 D16 Zones 9 16 D16 Option No Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 P125E Enable hardwired Zones on on on on on on on on on on on on on on on ON P125E Enable hardwired Zones Program Mode level Installer Factory De...

Page 73: ...Both PANIC Keys together 2E KPX SATURN enables double key FIRE Both FIRE keys 1 3 together 3E KPX SATURN Enables double key MEDICAL Both MEDICAL keys 4 6 together and enables MEDICAL on Navigator 4E Enables Entry Chime in Day mode Used to announce entry in Day mode 5E Enable Chime in Home Mode Used to announce entry in Home mode 8E Disable One Digit At A Time Display This allows Navigator keypads ...

Page 74: ...se by AutoTime Programming Steps Programming Steps HOME ARMED ARMED Arm or Disarm automatically at pre programmed times of day or day of the week This feature can save a site manager many headaches and hours of travel time There is no need to rely on staff remembering to arm or disarm the system Turn outputs on or off at pre programmed times every day once a week anytime Automate doors sprinkler s...

Page 75: ...d beeps P358E 6E AutoTimer2 keypad beeps P363E 6E AutoTimer3 keypad beeps P368E 6E AutoTimer4 keypad beeps P373E 6E AutoTimer5 keypad beeps P378E 6E AutoTimer6 keypad beeps P383E 6E AutoTimer7 keypad beeps P388E 6E AutoTimer8 keypad beeps This option enables a keypad beep to warn that an AutoTime action is due to begin Set the minutes for the start of the warning period The Keypad Beeps option for...

Page 76: ...rm Arms Area1 at the time day set by AutoTimer1 P353E 2E Area2 Arm Arms Area2 at the time day set by AutoTimer1 P353E 3E Home Arm Arms Home Mode at the time day set by AutoTimer1 Note Option 3E enables Home Arm for AutoTimers 1 to 6 but enables Day Mode Arm for AutoTimers 7 and 8 To Enable Disable User Codes by AutoTimer Note 1 P353E 4E Code Enable User Codes enabled for AutoTime become active fro...

Page 77: ...V RED J2 RECEIVER DATA WHITE RSSI BLUE OV BLACK Ness Radio Interface Part No 100 200 Ness D8x d16 Control Panel Notes The Ness Radio Interface should be installed outside the control panel to prevent interference from the control panel s electronics If the Radio Interface must be installed inside a metal enclosure the antenna wire should protrude outside the enclosure In cases where radio receptio...

Page 78: ...ignal on the radio device being programmed Example to program a radio PIR on zone 1 NOTE BEFORE Make sure that no other radio devices send a signal during this sequence to prevent progamming the wrong device The SMS string below enters program mode selects zone 1 deletes any existing device selects learn mode then the panel will wait for 10 seconds for a learn signal At this point you should inser...

Page 79: ...ould press the OFF button on the radio key Once the device is successfully programmed you will hear 3 beeps from the keypad The panel will exit program mode on expiry of the 30 second learn window SMS P MasterCode E P InstallerCode E P256E XE5EXE 0E 1E When the keypad displays READY TO RECEIVE OK press the OFF button on the radio key To Delete a radio Code Any Radio Code can be deleted as required...

Page 80: ...s allows high level interfacing with various external devices controllers dataloggers and other Messages are in ASCII format Due to space constraints the full protocol is not printed in this manual but is available on request KPX P199E xE to select one option as required Navigator P199E select one option as required SMS P MasterCode E P InstallerCode E P199E xE Or use NessXCEL app 1E ON Send Addre...

Page 81: ...e programmed remotely by SMS as long as a person is on site to present the card to the reader for programming Example to program an access card as user 55 The SMS string below enters program mode selects user 55 assigns the code to readers 1 2 and 3 deletes any existing code selects learn mode then the panel will wait for 30 seconds for a card to be enrolled At this point you should present the ca...

Page 82: ...sables zone 8 as an alarm zone When this option is enabled the panel will arm if a valid access card is presented to a reader once and zone 8 is unsealed momentarily within 5 seconds This option can be used to prevent accidental arming or disarming by access card P301E 4E DisArm with Access Card Factory Default ON When this option is enabled a valid access card will disarm the panel P301E 5E 7E Re...

Page 83: ...elects the zones that will generate a DOTL alert if the zone is unsealed for longer than the time set by P304E KPX P303E Zone Number E to enable disable zones Navigator P303E Select zones SMS P MasterCode E P InstallerCode E P303E Zone Number E Or use NessXCEL app P304E DOTL TIMER Program Mode level Installer Factory Default 20 seconds Related Options P303E DOTL Zones P121E 7E DOTL Alarms to AUX1 ...

Page 84: ...P117E 1E Enable Output Expander With this option on DOTL alerts will be sent to the optional Output Expander on the same output number as the DOTL zone number P305E 1E settings apply P305E 3E DOTL Timer In Minutes Related options P304E DOTL Timer With this option ON the P304E timer counts in minutes rather than seconds to give the option for longer DOTL times P305E 4E DOTL Timer In Hours Related o...

Page 85: ...erating door strikes magnetic locks etc Readers can be assigned to multiple outputs Always use an external relay board 101 283 on each Aux output on the output expander s if connecting devices which draw more than 100mA KPX PxxxE 1E 8E to enable disable the option as required Navigator PxxxE enable disable 1E 8E as required SMS P MasterCode E P InstallerCode E PxxxE 1E 8E as required Or use NessXC...

Page 86: ...to ground For cable runs exceeding 75m use the Ness Weigand data repeater Request To Exit REX using a keypad code Codes selected for Code Only Arming can be used as REX codes for access control functions That is the code can operate an output instead of arming disarming the panel There are two conditions needed to make the code operate as a REX code It is assigned to CODE ONLY ARM and it is not as...

Page 87: ...P210E ON 11 P211E ON 12 P212E ON 13 P213E ON 14 P214E ON 15 P215E ON 16 P216E ON 17 P217E ON 18 P218E ON 19 P219E ON 20 P220E ON 21 P221E ON 22 P222E ON 23 P223E ON 24 P224E ON 25 P225E ON 26 P226E ON 27 P227E ON 28 P228E ON 29 P229E ON 30 P230E ON 31 P231E ON 32 P232E ON 33 P233E ON 34 P234E ON 35 P235E ON 36 P236E ON 37 P237E ON 38 P238E ON 39 P239E ON 40 P240E ON 41 P241E ON 42 P242E ON 43 P243...

Page 88: ... Fail Alarm OFF 7E Exit BEEPS Full Arm off 8E Exit BEEPS Home Mode off Option Description Default Page P26E u Entry Delay Time 1 20 sec 25 P27E u Entry Delay Time 2 6 60 sec P28E u Exit Delay Time 60 sec P29E Siren Reset Time 5 min P30E Normal Zone Sensitivity all zones 26 P31E 36E Vibration Sensitivity High Low none P37E Long Response Zones 1 second none P38E Long Response Zones 3 seconds none P3...

Page 89: ...fault Page P88E 1E Send AREA 1 Open Close by CID OFF 54 55 2E Send AREA 2 Open Close by CID OFF See P194E for Open Close by SMS 3E Siren Chirp on Kiss off OFF 4E Flash Strobe on Kiss off OFF 5E Forced Opening report ON 6E Delayed Closing Reports OFF 7E Manual Exclude Reports ON 8E Auto Exclude Reports ON P89E 1E Enable Test Calls ON 56 2E Mains Report Delay 1 hour ON 3E not used OFF 4E Swinger shu...

Page 90: ...rs OFF 13E 22k EOL resistors OFF P141E 1E Area 1 Armed to AUX1 OFF 64 2E Area 2 Armed to AUX1 OFF 3E Home Armed to AUX1 OFF 4E Keypad toggle AUX1 OFF 5E not used OFF 6E not used OFF 7E not used OFF 8E Pulse AUX1 OFF Option Description Default Page P142E 1E Area 1 Armed to AUX2 OFF 66 2E Area 2 Armed to AUX2 OFF 3E Home Armed to AUX2 OFF 4E Keypad toggle AUX2 OFF 5E not used OFF 6E not used OFF 7E ...

Page 91: ...E 1E Use reader addresses OFF 82 2E Arm with double read ON 3E Arm with single read and pushbutton OFF 4E Disarm with access card ON 5E REX Input 1 Zone 5 input OFF 6E REX Input 2 Zone 6 input OFF 7E REX Input 3 Zone 7 input OFF 8E Strobe Flash on Arm Disarm by Reader ON P303E DOTL zones none 83 84 P304E DOTL time 20 sec P305E 1E DOTL output LATCHES OFF 2E DOTL outputs to Output Expander OFF 3E DO...

Page 92: ...P374E 1E AREA 1 disarm 2E AREA 2 disarm 3E HOME disarm 4E Uses AUX7 8 not AUX3 4 5E AUX3 TOGGLE 6E AUX3 PULSE 7E AUX4 TOGGLE 8E AUX4 PULSE AutoTimer 6 P375E Minutes 0 59 P376E Hours 0 23 P377E Days 1 Sunday P378E 1E AREA 1 arm 2E AREA 2 arm 3E HOME arm 4E Code Enable 5E Code Disable 6E KEYPAD Beeps 7E RESET O P Beeps 8E Extend AutoTIME P379E 1E AREA 1 disarm 2E AREA 2 disarm 3E HOME disarm 4E Uses...

Page 93: ...put expander s SERIAL header Serial data port for optional ethernet module or direct connect programming using NessComms software READER header Multi pin port for connecting up to 3 Ness proximity access card readers Siren On board siren driver with timed output Maximum 3 x 8 Ohm horn speakers Strobe 12V DC timed output Maximum 2 x 1 Watt strobe lights Reset 12V DC timed output Maximum 3 x 12V pie...

Page 94: ...Ready Light to OK icon p17 typo deleting codes via sms p56 Added P89E 6E Master Code Clears dial attempts p21 improved text output examples p52 enhanced P86E 1E notes Disabling the dialler also clears the SMS and reporting queue While the dialler is disabled the keypad s will show Signal Strength level 0 zero even if a SIM card remains fitted P17 added Toggle Over ride commands Z U release NOTES I...

Page 95: ...ER CODE USER CODE USER CODE OPTION No OPTION No OPTION No Extra Options Assigned E g Radio Code Arm Only etc Extra Options Assigned E g Radio Code Arm Only etc Extra Options Assigned E g Radio Code Arm Only etc 1 20 39 P201E P220E P239E Master Code 2 21 40 P202E P221E P240E 3 22 41 P203E P222E P241E 4 23 42 P204E P223E P242E 5 24 43 P205E P224E P243E 6 25 44 P206E P225E P244E 7 26 45 P207E P226E P...

Page 96: ......

Reviews: