AUx1
OUTPUT OPTIONS
Any or all of the P141E options may be selected.
Option No.
Description
Default
P141E
1E
Area 1 Armed to AUX1
OFF
2E
Area 2 Armed to AUX1
OFF
3E
Home Armed to AUX1
OFF
4E
Keypad toggle AUX1
OFF
5E
[not used]
OFF
6E
[not used]
OFF
7E
[not used]
OFF
8E
Pulse AUX1
OFF
Only one of the P121E options may be selected.
Option No.
Description
Default
P121E
1E
Zone alarms to AUX1
(p58e selects zones)
ON
2E Zone Supervision alarms to AUX1
OFF
3E Radio key Panic TOGGLE
OFF
4E Radio key Panic PULSE
OFF
5E
[not used]
OFF
6E
[not used]
OFF
7E
door Open Too Long (dOTL) alarm to aUX1
OFF
8E
Reader [x] output pulses AUX1
OFF
P121E
AUx1 oPtions 1E - 8E
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
1E on.
notEs
Only one option can be on. Turning an
option on turns off another.
rELAtED oPtions
P141E 1E-8E, P354E 5E-6E,
P359E 5E-6E, P364E 5E-6E,
P369E 5E-6E
Enable or disable P121E 1E to 8E as required. Only one option can be on.
KPX+
P121E 1E - 8E to enable/disable the option as required
NAVIGATOR
P121E > enable/disable 1E - 8E as required
SMS*
P[MasterCode]E P[InstallerCode]E P121E [1E -8E] as required
Or use
NessXCEL
app
P121E 1E
ZonE ALArms to AUx1
rELAtED oPtions
P58E Aux1,3 zones
With this option ON, zones selected in P58E will turn on Aux1 when they go into alarm. The
Aux1 output turns off when the panel is disarmed/reset.
P121E 2E
ZonE sUPErVision ALArms to AUx1
rELAtED oPtions
P65E, P66E, P67E Radio Supervision
With this option ON, the AUX1 output will turn on when a SUPERVISED RADIO alarm is
triggered. The Aux1 output turns off when the panel is disarmed/reset.
P121E 3E
EnAbLE AUx1 For AUtotimEr / rADio kEy PAniC toggLEs AUx1
notEs
When this option is on, Radio Key Panic
buttons will no longer sound alarms or
report alarms by dialler.
rELAtED oPtions
P350E to P369E. AutoTimers 1 to 4.
Dual action programming option.
When this option is on, AUX1 is enabled for use by AutoTimer and Radio Key/s Panic
button will TOGGLE the Aux1 output.
P121E 4E
rADio kEy PAniC PULsEs AUx1
notEs
When this option is on, Radio Key Panic
buttons will no longer sound alarms or
report alarms by dialler.
rELAtED oPtions
P145E AUX1 Timer
When this option is on, Radio Key/s Panic button will PULSE the Aux1 output.
P121E 7E
Door oPEn too Long (DotL) ALErts to AUx1
rELAtED oPtions
P303E DOTL zones.
P304E DOTL timer.
This option enables DOTL zones (P303E) to turn on Aux1 when the DOTL Time (P304E)
expires.
P121E 8E
Door oPEn too Long (DotL) ALErts to AUx1
rELAtED oPtions
P318E, P328E, P338E, P319E, P329E,
P339E.
This option enables an access control reader to pulse Aux1 when a valid access card is
presented. Set the reader using P318E, P328E or P338E.
* SMS programming shows the full SMS string to send. KPX+ and
NAVIGATOR programming assumes the panel is already in program mode.
63
NESS D8XCEL / D16XCEL CONTROL PANEL – INSTALLATION MANUAL REV 1.1