P94E
no mEmory WArning ZonEs
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
no zones selected.
notEs
Applies to zones 1-8 only for both
D8XCEL and D16XCEL
Select zones that do not flash the Memory indicator on the keypad/s. Alarm events on
those zones are still stored in memory and can be reviewed as normal.
KPX+
P94E [Zone Number] E to enable/disable zones
NAVIGATOR
P94E > Select zones
SMS*
P[MasterCode]E P[InstallerCode]E P94E [Zone Number] E
Or use
NessXCEL
app
ZONES 1–8
(D8 & D16)
Option No. Description
1 2 3 4 5 6 7 8
P94E
"NO MEMORy WARNING"ZONES
* SMS programming shows the full SMS string to send. KPX+ and
NAVIGATOR programming assumes the panel is already in program mode.
KPX+
PRO TIP
When selecting zones,
mEmory E
selects all zones,
0 E
deselects all zones
P89E 5E
LinE FAULt monitor
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
OFF: No Line Fault Monitor.
rELAtED oPtions
P122E 5E Line Fault to AUX2
When this option is enabled the keypad/s will display cellular signal errors.
If the cellular signal is low or absent KPX keypad will flash CELL 00, Navigator displays Line
Fault.
KPX+
P89E 5E to enable/disable the option
NAVIGATOR
P89E > enable/disable 5E
SMS*
P[MasterCode]E P[InstallerCode]E P89E 5E
Or use
NessXCEL
app
P89E 6E
mAstEr CoDE CLEArs DiAL AttEmPts
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
OFF
When this option is enabled, any keypad or SMS command using the master Code (User
code 1) resets the re-dialling attempts to zero. The effect is to restart the dialling queue and
send any queued dialler reports immediately.
KPX+
P89E 6E to enable/disable the option
NAVIGATOR
P89E > enable/disable 6E
SMS*
P[MasterCode]E P[InstallerCode]E P89E 6E
Or use
NessXCEL
app
57
NESS D8XCEL / D16XCEL CONTROL PANEL – INSTALLATION MANUAL REV 1.1
P r o g r A m m i n g