rADio DEViCE ProgrAmming
Each of the zones of the D8x or D16x can be a radio zone. Once programmed, zones
can accept both radio devices and normal zone inputs simultaneously.
The optional 100–200 Ness Radio Interface is required for radio devices to operate.
A radio device is any type of Ness transmitter including Radio PIR, Radio Reed
Switches, Radio Smoke Detector.
Up to 8 (D8) or 16 (D16) radio devices can be enrolled, one per zone.
PROGRAMMING RADIO DEVICES By KEyPAD
KPX+
NaVIGaTOr
Applies to Radio PIRs, Radio Pendant, Radio Smoke Detector.
Select a zone using P101E – P116E (options P109E–P116E apply to D16 only).
If the zone already has a Radio Device programmed the KPX ARMED light will be ON. Or on
Navigator keypad 'Radio Programmed' will display. Press 0E (or Delete Device) to delete.
KPX+
Press 1E (The OK icon will turn ON to indicate the zone is ready to accept
the Radio Device.)
NaVIGaTOr
Press
Send a Learn signal from the radio device by inserting the battery.
A. If the Radio Device is accepted, the OK icon will turn off, the ARMED light will turn
on and 3 beeps will sound. On the Navigator keypad 'Radio Programmed' will display.
B. If an error beep sounds, the Radio Device is already assigned to another zone and
must be cleared from that zone first.
C. If SUPERVISED SIGNALS have also been successfully recognised, the TAMPER light
will turn ON.
ExAmPLE: to program a radio Pir on zone 1:
P101E 1E (or press Program Device)
Insert the battery in the Radio PIR
PROGRAMMING SEQUENCE – WITH RESTORALS
Suitable for Radio Reed Switches.
The procedure is same as above however at Step 3 you will transmit the Restore signal.
Before beginning the programming steps make sure the reed switch battery is inserted then move
the magnet away from the reed switch and leave it separated. Then proceed with steps 1 & 2
above. At step 3, move the magnet to the reed switch to send a restoral signal as the learn signal.
PROGRAMMING RADIO DEVICES By SMS
SmS
Radio devices can be programmed remotely by SMS but of course somebody must be on site to
initiate the learn signal on the radio device being programmed.
Example, to program a radio PIR on zone 1.
NOTE BEFORE. Make sure that no other radio devices send a signal during this sequence to
prevent progamming the wrong device.
The SMS string below enters program mode, selects zone 1, deletes any existing device, selects
learn mode, then the panel will wait for 10 seconds for a learn signal. At this point you should insert
the batteries in the radio PIR. Once the device is successfully programmed you will hear 3 beeps
from the keypad. The panel will exit program mode on expiry of the 10 second learn window.
SMS
P[MasterCode]E P[InstallerCode]E P101E 0E P101E 1E
DELETING A RADIO DEVICE
Use P101E to P116E to select the zone
KPX+
Press 0E to clear the device
(3 beeps will sound)
NaVIGaTOr
Press
SmS
add 0E after the option number. eg, to delete the radio device on zone 1,
send P[MasterCode]E P[InstallerCode]E P101E 0E
TiP:
To prevent
conflicting radio signals
when programming Radio
Devices, disable each
device once you have finished
programming it. (Remove the
battery).
Remember to enable all the
devices when programming is
completed.
RADIO DEVICES - OPTION TABLE
D8 & D16
Zone 1
P101E
Zone 2
P102E
Zone 3
P103E
Zone 4
P104E
Zone 5
P105E
Zone 6
P106E
Zone 7
P107E
Zone 8
P108E
D16
Zone 9
P109E
Zone 10
P110E
Zone 11
P111E
Zone 12
P112E
Zone 13
P113E
Zone 14
P114E
Zone 15
P115E
Zone 16
P116E
100–662
mini radio
Reed Switch
106–091
micro radio
Reed Switch
106-168 LUX radio pIr
106-170 LUX peT radio pIr
100–527
Universal Transmitter
P101E – P116E
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
No Radio Devices programmed.
notEs
• Radio Device programming is done
by ‘learning’ the code by radio.
• Radio Devices can be prgrammed
and deleted by keypad or SMS.
• Some Ness Radio Devices send
separate Alarm and Restore signals.
• For special purposes, radio zones
can be also programmed to accept
radio keys. In this case the zone can
not also be programmed to accept a
radio device.
• Late model Ness Radio PIRs and
Radio Reed Switches send Supervision
signals.
sUPErVision rELAtED oPtions
P65e
Supervised Radio Zones.
P66e
Radio Supervision Alerts.
P67e
Radio Supervision Time.
P75e 12e
Radio Supervision Fail Report.