CONNECTION DIAGRAMS
8
NESS D8XCEL / D16XCEL CONTROL PANEL – INSTALLATION MANUAL REV 1.1
20V DC
POWER SUPPLy
If required, this control panel can alternatively be
powered by a 17VAC (1.4A) plug pack.
Install the cellular
antenna in a location
providing the best
signal strength as
indicated by the keypad
signal strength display.
The antenna should not
be installed inside the
control panel housing.
Part No.
840-054
20VDC Non-polarity
17VAC Non-polarity
17VAC or
20VDC
Power InPut
non-PolArIty
17V AC
POWER SUPPLy
3G
ANTENNA
yellow/Green
To panel earth (optional)
Part No.
840-029
A 20VDC power supply is included with most
D8XCEL/D16XCEL models (Australia only).
This power supply has positive and negative 20VDC
output however the polarity is not important in this
case.
Brown
Blue
17VAC or
20VDC
Power InPut
non-PolArIty
DUAL VoLtAgE PoWEr inPUt
20VDC or 17VAC
J1
3G Antenna
socket
3m cable
Antenna has a
magnetic base and
self-adhesive disc
for affixing to non-
metallic surfaces
K
ey
PAD
17VAC or
20VDC
Power InPut
non-PolArIty
12V
BA
tter
y
BAttery leADS
reCeIVer
optional ness radio
Interface
3G Antenna
socket
AuX outPutS 1~4
and connection for
output expander/s
SerIAl
rS232 serial port
Sealed/Normal State
link on or tamper connected
oPeN/alarm State
Power up with link off to enter
installer program mode
J1 lInK
Box tamPer & Program liNk
reADer
Connection for up to 3 ness
weigand readers.
Also used for ness PD
Portable Download tool.
reD +
reD +
re
AD
er
S
er
IA
l
0V
F6
AuX1
AuX2
AuX3
AuX4
+12V
ne
SS
r
ADI
o
re
C
e
IV
er
uSB
Future uSe
S
im
3G
SIren
F1
F1
F7
F2
F2
F3
reSet
+12V
+12V
0V
Z9
Z10
Z12
Z14
Z11
Z13
Z15
Z16
C
C
C
C
0V
Z1
Z2
Z3
Z4
Z5
Z6
Z7
Z8
tamP
N.o tamPer SWitCH
(761-002) Colour: BlACK
Supplied with ness siren covers
12VDC outPut
enD oF lIne reSIStorS
the default end of line resistor value is 2k2 (2200 ohms). the eol
value is fully programmable with a choice of 13 resistor values,
see program option P129e. ness panels are supplied with 2k2 1%
tolerance metal Film resistors.
Colour code: red, red, Black, Brown, Brown.
normally Closed
(n.C.) Devices
Zone wIrInG
normally open
(n.o.) Devices
Zone 8
Zone 7
Zone 6
Zone 5
Zone
SenSor
SenSor
Zone
C
C
Zone 4
Zone 3
Zone 2
Zone 1
12V DC output for detectors.
500ma max. from all 12V outputs.
Auto reset fuse protected.
Up to 3 x 12V Screamer (100-238, 100-004)
Up to 2 x Strobe light (Noi-300)
Up to 3 x Horn Speaker, 8 ohm (Noi-110)
non-polarity
Keypad connection (Alternative)
Box tamPer SWitCH (White) N.C.
contacts. Connect to J1.
Jumper remains fitted if not using internal
tamper switch.
Heartbeat led - Flashing ok
maximum 3 mixed
keypads or 4 navigator
keypads per system.
maximum cable length
100m (all keypads
combined).
nAVIGAtor
SAturn
KPX+
DAt (Blue)
ClK (white)
Com (Black)
+12V (red)
Zones
1~8 D8XC
eL
& D16XC
eL
Zones
9~16 D16XC
eL
only
D8XCeL
D16XCeL
Main Board
alterNatiVe tamPer SWitCH
WiriNg for N.C tamPer SWitCH
(SWi920) Colour: WHite
3G
SIG
n
A
l
Fla
SH
ok
3G
AntennA
+12V
0V
C
C
C
C
+12V
Com
K
ey
PAD
ClK
DAt
Str
If the 3G signal leD is not
flashing Sim card may not
be inserted or inactive
Summary of Contents for D16XCEL