P87E 1E
sPLit DiAL PrimAry/sEConDAry PhonE nUmbErs
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
OFF: Split Dial.
rELAtED oPtions
P87E 4E Number of Dialling attempts.
This option selects the order in which Telephone numbers 1 & 2 are dialled.
Option OFF: Split Dial. Dial Telephone No.1 for half of the call attempts. If unsuccessful, dial
Telephone No.2 for the last half of call attempts.
Option ON: Alternate Dial. Dial Telephone No.1 on the first attempt. If no answer, dial
Telephone No.2.
Continue alternating until successful.
KPX+
P87E 1E to enable/disable the option
NAVIGATOR
P87E > enable/disable 1E
SMS*
P[MasterCode]E P[InstallerCode]E P87E 1E
Or use
NessXCEL
app
P87E 3E
EnAbLE rEPorting by sms
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
On: SMS reporting enabled.
rELAtED oPtions
P180E to P189E Phone numbers for
SMS reporting
P86E 2E Enable reporting by Contact
ID
notEs
• This option affects only outgoing
reporting by SMS so if the option is
disabled the panel will still reply to
incoming SMS commands.
This option enables reporting to mobile phones by SMS messaging via SMS phone
numbers programmed at P180E to P189E
KPX+
P87E 3E to enable/disable the option
NAVIGATOR
P87E > enable/disable 3E
SMS*
P[MasterCode]E P[InstallerCode]E P87E 3 E
Or use
NessXCEL
app
P87E 4E
nUmbEr oF DiALLing AttEmPts
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
ON: 4 dialling attempts.
notEs
• Sets the total number of dialling
attempts. E.g. If 4 dialling attempts is
selected, this means 2 attempts per
telephone number.
rELAtED oPtions
P87E 1E Split Dial
Sets the number of dialling attempts when sending reports to a Central Station.
OFF: sets a maximum 10 dial attempts before a 5 minute sleep and 10 more re-tries if
unsuccessful.
ON: allows a maximum of 4 dial attempts before a 5 minute sleep and 4 more retries if
unsuccessful.
If all attempts fail the dialler waits for the next trigger event. The previously unsuccessful
report will be included in the new message.
When sending Test Calls, the time between dialling attempts increases to 60 minutes for
the second round of dialling. If a Test Call is unsuccessful after the first round of calls are
made, another call is made after 5 minutes. If this call fails then subsequent calls are made
every hour (up to the maximum number of calls).
KPX+
P87E 4E to enable/disable the option
NAVIGATOR
P87E > enable/disable 4E
SMS*
P[MasterCode]E P[InstallerCode]E P87E 4E
Or use
NessXCEL
app
Option No.
Description
Default
P87E
1E
Split dial Primary/Secondary numbers
OFF
2E
[not used]
OFF
3E
Enable reporting by SMS
ON
4E
4 Dialling attempts
ON
* SMS programming shows the full SMS string to send. KPX+ and
NAVIGATOR programming assumes the panel is already in program mode.
53
NESS D8XCEL / D16XCEL CONTROL PANEL – INSTALLATION MANUAL REV 1.1
P r o g r A m m i n g
Summary of Contents for D16XCEL
Page 96: ......