D8XCEL and D16XCEL control panels can be operated and programmed by SMS (TXT)
messaging from any mobile phone.
The NESS XCEL free app is also available for easy operation for users and fast
programming by installers.
This section covers programming by direct SMS messaging from a mobile phone if not
using NESS XCEL app.
PROGRAMMING By SMS FROM ANy SMARTPHONE
SMS programming commands are sent to the XCEL panel in essentially the same format
as programming using a KPX+ or Saturn keypad.
Examples using the factory default master code: 123
ExAmPLE 1
Program the Entry Delay time to be 15 seconds
SMS SENT TO THE PANEL
SMS REPLy
P123E P26E 15E
Entry Delay can be programmed in User Program
Mode so the installer code is not required.
This command is ok to send without spaces, ie.
P123EP26E15E will also work.
M123E ACK
M26E ACK
15E ACK
ME ACK
The command comprises of three parts, where...
P123E
P26E
15E
Enters user program
mode. 123 in this case
is the Master code.
The option number for
Entry Delay
Programs Entry Delay to
be 15 seconds
ExAmPLE 2
Program User Code 2 to be 5678.
SMS SENT TO THE PANEL
SMS REPLy
User Codes can be programmed in User
Program Mode so the installer code is not
required.
M123E ACK
M202E ACK
5678E ACK
5678E ACK ME ACK
ExAmPLE 3
Sending multiple commands.
For example, to program all these changes in one message.
User code 6 change to 3456
Entry Delay change to 20 seconds
Exit Delay change to 50 seconds
Siren Time change to 3 minutes
Zone 2 change to an entry delay zone
SMS SENT TO THE PANEL
SMS REPLy
P123E P000000E P206E 3456E 3456E
P26E 20E P28E 50E P29E 3E P41E 2E
This command requires both the master Code
and Installer Code to be included
.
M123E ACK M000000E ACK M206E
ACK 3456E ACK 3456E ACK M26E
ACK 20E ACK M28E ACK 50E ACK
M29E ACK 3E ACK M41E ACK 2E
ACK ME ACK
sms ProgrAmming CommAnDs
ProgrAmming by sms
SMS commands are extremely flexible in
their format.
mULtiPLE CommAnDs
you can send multiple programming
commands in one text message - in fact
the message can be as long as the SMS
limit of 160 characters per single message.
See the Installer Manual for detailed
instructions.
UsE oF sPACEs
The panel automatically ignores spaces in
most SMS commands. However, spaces
are important in Text Output commands,
see page 21.
UPPEr or LoWEr CAsE is ok
you can use either UPPER CASE or lower
case characters in your messages, or even
mixed case without a problem.
But
bEWArE oF CommAs
Commas are used to separate words
when reprogramming text output, so use
commas only when the command allows it.
sms rEPLiEs:
The panel replies to
each programming command with a
confirmation message.
ACk
(Acknowledged) :ACK is the panel
saying ‘Command received and applied’.
nAk
(Not Acknowledged): The ‘NAK’
response indicates that the command
was not accepted by the panel. Check
the format of your SMS or perhaps the
command should have been sent in
Installer program mode.
toggLE oVEr-riDE
With some options U and Z can replace E
to ensure an option is ON or OFF instead
of toggled.
Example:
P39E1E toggles option 1
P39E1U sets ON option 1
P39E1Z sets OFF option 1
For experienced installers only, works only
with 'AND' program options.
To
DELEtE
a user code or phone number,
enter V in place of the number.
Example 1.
P123EP000000EP180EVE deletes SMS
phone number 1.
Example 2.
P123EP000000EP202EVE deletes User
code 2.