Howler Tone Service
Description
Howler Tone Service provides a Howler Tone when a station remains off-hook after a call is completed
or when a station is off-hook and digits are not dialed in a programmed time.
Conditions
Howler tone is generated 30 seconds after a call is disconnected and the telephone is left off-hook or
the telephone is left off-hook without dialing.
Default Settings
Enabled
System Availability
Terminals
All Terminals
Required Component(s)
None
Related Features
None
Guide to Feature Programming
Program Number
Program Name
Default
20-18-02
Service Tone Timers - Busy Tone Timer
15 (seconds)
80-01-01
Service Tone Setup - Repeat Count
Refer to Programming Manual.
80-01-02
Service Tone Setup - Basic Tone Number
Refer to Programming Manual.
Operation
None
ISSUE 1.0
SL1000
H
Howler Tone Service
1-250
Summary of Contents for SL1000
Page 1: ...Features and Specifications Manual A50 031169 001 ISSUE 1 0 January 2011 ...
Page 41: ...Operation None ISSUE 1 0 SL1000 A Features and Specifications Manual 1 33 ...
Page 57: ...Operation None ISSUE 1 0 SL1000 B Features and Specifications Manual 1 49 ...
Page 95: ...Operation None ISSUE 1 0 SL1000 C Features and Specifications Manual 1 87 ...
Page 154: ...Operation None ISSUE 1 0 SL1000 D Data Line Security 1 146 ...
Page 324: ...Operation LCR Operation Flow Diagram ISSUE 1 0 SL1000 L LCR Least Cost Routing 1 316 ...
Page 325: ...LCR Dial LCR Dial Editing ISSUE 1 0 SL1000 L Features and Specifications Manual 1 317 ...
Page 326: ...LCR Cost Centre Code ISSUE 1 0 SL1000 L LCR Least Cost Routing 1 318 ...
Page 586: ...Memo ISSUE 1 0 SL1000 Features Availability by Software Revision 3 6 ...
Page 587: ...Memo ISSUE 1 0 SL1000 Features and Specifications Manual 3 7 ...
Page 588: ...Features and Specifications Manual NEC Corporation ISSUE 1 0 ...