Upgrading Your Server 11-25
NOTE:
The CPU must be installed in correct direction, as shown in
the figure below.
FRONT
12.
Secure the heat sink with four screws.
Temporarily tighten the four screws on cater corner, then tighten them securely after
making sure that the heat sink has been seated.
1
3
4
2
13.
Make sure that the heat sink is level with the mother board.
IMPORTANT:
If the heat sink is not level, remove it, and then install it again. If the
CPU is not positioned correctly, it causes the heat sink not to be
level.
Do not move the secured heat sink.
If you install an additional CPU, you need to change DIMM
installation location. See "DIMM" for details.
14.
Install the duct cover, and secure it with a setscrew.
15.
Set [Reset Configuration Data] on the [Advanced] menu to "Yes".
This is required to update the hardware configuration information. See Chapter 4 for
details.
16.
To add one or more CPUs to the server in 1-CPU configuration to operate the server with
more than one CPU, do the following:
Change the driver of [Computer] in the [Device Manager] to [ACPI multi-processor PC]
and then update the system (see Chapter 5, 6, or 7).
Summary of Contents for N8100-1575F
Page 16: ...x This page is intentionally left blank...
Page 34: ...1 18 Notes on Using Your Server This page is intentionally left blank...
Page 158: ...5 30 Installing Windows Server 2008 4 Activate Windows The Windows activation is complete...
Page 256: ...8 12 Installing and Using Utilities This page is intentionally left blank...
Page 268: ...9 12 Maintenance This page is intentionally left blank...
Page 372: ...C 2 IRQ This page is intentionally left blank...
Page 374: ...D 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Page 378: ...E 4 Product Configuration Record Table This page is intentionally left blank...