Configuring Your Server 4-49
The setting level of Universal RAID Utility and the setting value
Item
Setting level of Universal
RAID Utility
Setting value
High
90
Middle
50
Rebuild Priority
Rebuild Rate (LSI Software
RAID Configuration Utility)
Low
10
High
90
Middle
50
Consistency Check Priority
Chk Const Rate (LSI Software
RAID Configuration Utility)
Low
10
NOTES:
LSI Software RAID Configuration Utility can set FGI Rate
(Foreground Initialize) and BGI Rate (Background Initialize
Priority). But Universal RAID Utility can't set it.
Universal RAID Utility can set Initialization Priority, but it can't set
it to the LSI Embedded MegaRAID
. Therefore, Universal RAID
Utility doesn't display [Initialization Priority] in the property of
RAID Controller. Also, it will fail that you change the Initialization
Priority by raidcmd.