Upgrading Your Server 11-23
IMPORTANT:
Keep the protective cover for future use. Always mount the socket
cover if the CPU is removed from the socket.
Do not touch the socket contacts.
6.
Take out the new CPU and remove the protective cover.
IMPORTANT:
Hold the CPU only at the edges. Be careful not to
touch the bottom of the CPU (pin portion).
7.
Place the CPU on the socket slowly and carefully.
Hold the CPU with your thumb and index fingers oriented as shown in the figure below.
NOTES:
Align notches with the key on the socket.
Bring the CPU straight down without tilting or sliding it in the
socket.
Pin mark
Key
Notch
Pin mark