5. RAID System Configuration
Express5800/R120f-2E, T120f Maintenance Guide
170
Chapter 2 Useful Features
5.8
Off-line Utility and Universal RAID Utility
The points to be noted when using Universal RAID Utility together with Off-line Utility are described below.
The name of Off-line Utility depends on Boot Mode. In Legacy Mode, Ctrl-R is used. In UEFI Mode, HII is used.
(1)
Terms
Some terms are different between Off-line Utility and Universal RAID Utility. When using Universal RAID Utility
together with Off-line Utility, replace the terms as shown in the table below:
Terms of Off-line Utility
Terms of Universal RAID Utility
RAID Viewer
raidcmd
Controller
RAID Controller
RAID Controller
Virtual Drive
Logical Drive
Logical Drive
Drive Group
Disk Array
Disk Array
Drive
Physical Device
Physical Device
Tips
raidcmd
is a command provided by Universal RAID Utility. See Universal RAID Utility
User’s Guide for details.
(2)
Numbering
The numbers indicating RAID controller information differ between Off-line Utility and Universal RAID Utility as
shown in the table below.
See Universal RAID Utility Users Guide for details.
Item
Number
Off-line Utility
Universal RAID Utility
Controller (RAID Controller)
Starts from 0
Starts from 1
Virtual Drive (Logical Drive)
Starts from 0
Starts from 1
Drive group (Disk Array)
Starts from 0
Starts from 1
Drive (Physical Device)
Starts from 0
To be assigned based on an
enclosure that contains the
physical device and its slot
number.