1. POST Error Message
Express5800/R120f-2E, T120f Maintenance Guide
189
Chapter 3 Appendix
Error Message
Cause
Solution
A428
Cluster On Die was not ready.
Cluster On Die feature is
disabled in this hardware
configuration.
Replace the processor with the one that supports
this feature. Or, run SETUP and select
Disabled
for the
Cluster On Die
. If the same error persists,
contact your sales representative.
A429
DIMM population is
insufficient for Cluster On
Die.
Cluster On Die feature is
disabled in this memory
configuration.
Check if memory configuration is correct. If the
same error persists, contact your sales
representative.
A800
Memory not detected
No valid memory is installed.
Check if DIMMs are properly installed. If the same
message appears repeatedly, contact your sales
representative.
A804
Latest memory module is
corrupted.
Failure on BIOS Flash ROM
was detected.
Contact your sales representative.
AE01
CPU1_DIMM1 has been
disabled.
A memory error was detected.
CPU1_DIMM1 has been
disabled.
AE02
CPU1_DIMM2 has been
disabled.
A memory error was detected.
CPU1_DIMM2 has been
disabled.
AE03
CPU1_DIMM3 has been
disabled.
A memory error was detected.
CPU1_DIMM3 has been
disabled.
AE04
CPU1_DIMM4 has been
disabled.
A memory error was detected.
CPU1_DIMM4 has been
disabled.
AE05
CPU1_DIMM5 has been
disabled.
A memory error was detected.
CPU1_DIMM5 has been
disabled.
AE06
CPU1_DIMM6 has been
disabled.
A memory error was detected.
CPU1_DIMM6 has been
disabled.
AE07
CPU1_DIMM7 has been
disabled.
A memory error was detected.
CPU1_DIMM7 has been
disabled.
AE08
CPU1_DIMM8 has been
disabled.
A memory error was detected.
CPU1_DIMM8 has been
disabled.
AE0D
CPU2_DIMM1 has been
disabled.
A memory error was detected.
CPU2_DIMM1 has been
disabled.
AE0E
CPU2_DIMM2 has been
disabled.
A memory error was detected.
CPU2_DIMM2 has been
disabled.
AE0F
CPU2_DIMM3 has been
disabled.
A memory error was detected.
CPU2_DIMM3 has been
disabled.
AE10
CPU2_DIMM4 has been
disabled.
A memory error was detected.
CPU2_DIMM4 has been
disabled.
AE11
CPU2_DIMM5 has been
disabled.
A memory error was detected.
CPU2_DIMM5 has been
disabled.
AE12
CPU2_DIMM6 has been
disabled.
A memory error was detected.
CPU2_DIMM6 has been
disabled.
AE13
CPU2_DIMM7 has been
disabled.
A memory error was detected.
CPU2_DIMM7 has been
disabled.
AE14
CPU2_DIMM8 has been
disabled.
A memory error was detected.
CPU2_DIMM8 has been
disabled.
AE81
CPU1_DIMM1 with error is
enabled.
An error in CPU1_DIMM1 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
AE82
CPU1_DIMM2 with error is
enabled.
An error in CPU1_DIMM2 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.