5. Troubleshooting
Express5800/R120f-2E, T120f Maintenance Guide
28
Chapter 1 Maintenance
5.
Troubleshooting
If this system does not operate as intended, check it according to the contents of the following checklist before
sending it for repair. If an item in the checklist corresponds with a problem you are experiencing, follow the
subsequent check and processing instructions.
If the system still does not operate normally, write down the messages displayed on the screen and then contact
your sales representative.
5.1
Problem of Powering On
[?]
Fail to power on the server
Is the server properly supplied with power?
→
Check if the power cord connects to the power outlet (or UPS) that meets the power specifications for the
server.
→
Use the power cord that comes with the server. Additionally, check the power cord for broken shield or
bent plugs.
→
Make sure the power breaker for the connected power outlet is on.
→
If the power cord is plugged to a UPS, make sure the UPS is powered and it outputs power. Refer to the
manual that comes with the UPS for details.
Power supply to the server may be linked with UPS using the BIOS Setup utility.
Are STATUS LEDs being lighted?
→
Wait until both STATUS LEDs are unlit and press POWER Switch on the front of the server.
Is
Standby Power Save
set to
Enabled
in BIOS settings?
→
Press POWER Switch twice to start up the server.
[?]
The screen is not displayed
→
Wait until the NEC logo appears.
[?]
The screen is sometimes changed to the black screen during POST process
Are the BIOS settings of option ROM scan for plural on-board LANs specified to
Enabled
?
→
Ignore the black screen and wait until POST ends.