4-14
Disassembly and Reassembly
CPU Installation
1.
Observe the safety and ESD precautions listed under
General Information
and
Static Precautions
at the beginning of this chapter.
2.
Open the front bezel of your system's cabinet.
3.
Shutdown the operating system (OS).
4.
Press the power on/off switch on the front panel of the server (see
Front View
in Chapter 1). The power-on LED goes out.
5.
Power off the peripheral devices.
6.
Unplug the system power cord(s) from the AC wall outlet(s).
Note:
If the system power cord is connected to a power
control unit such as an UPS (Uninterruptible Power Supply),
refer to the UPS user's guide for proper power-off
procedures.
7.
Remove the left-hand side access panel of the system chassis following
procedures previously described in this chapter.
!
CAUTION
For proper cooling and airflow, do not operate the system
with the side access panel removed. Always
replace
the
panel before powering on the system.
8.
Remove the processor air duct. See
Processor Air Duct Removal
earlier in
this chapter.
9.
Locate the CPU socket which you are going to install CPU.
10.
Raise the locking lever on the socket. See Figure 4-7.
IMPORTANT:
Open the lever until it stops. The bar can be opened to
approx. 120 degrees.
Summary of Contents for Express 5800/120Lg
Page 1: ... S e r v i c e G u i d e EXPRESS5800 120Lg ...
Page 2: ......
Page 4: ......
Page 10: ......
Page 73: ...Disassembly and Reassembly 4 7 Figure 4 2 Installing the Left Hand Side Access Panel ...
Page 132: ......
Page 161: ...6 Illustrated Parts Breakdown Exploded View Field Replaceable Units ...
Page 168: ......
Page 169: ...A Specifications System Specifications ...
Page 179: ...C IRQ and I O Port Addresses Interrupt Requests PIRQ and PCI Device ...
Page 188: ......
Page 198: ......
Page 203: ...xx ...
Page 204: ... 456 01673 000 ...