Configuring Your System 3-13
Server Menu (Continued)
Feature
Choices or Display
Only
Description
Your Setting
Boot
Monitoring
Policy
Retry 3 Times
Retry Service Boot
Always Retest
This item indicates the processing at
the occurrence of timeout during boot
monitoring.
If [Retry 3 times] is selected, the system
is reset after the occurrence of timeout
and OS boot is retried up to three times.
The failure in the third boot causes the
boot to be tried from the service
partition*.
If [Retry Service Boot] is selected, the
system is reset after the occurrence of
timeout and OS boot is retried up to
three times. Then the boot is tried from
the service partition for three times. The
system halts if the system fails to boot
from the service partition.
If [Always Reset] is selected, the
system is reset after the occurrence of
timeout and OS boot is retried
repeatedly.
* If no service partition exists in the
system, BIOS continues to bootup
from the system partition.
System Management Submenu
Feature
Choices or
Display
Only
Description
Your Setting
Board Part Number
–
Indicates the part number of mother
board. (View only)
Board Serial Number
–
Indicates the serial number of mother
board. (View only)
System Part Number
–
Indicates the system part number. (View
only)
System Serial Number
–
Indicates the serial number of system.
(View only)
Chassis Part Number
–
Indicates the part number of chassis.
(View only)
Chassis Serial Number
–
Indicates the serial number of chassis.
(View only)
BIOS Version
–
Indicates BIOS version number. (View
only)
BMC Device ID
–
Indicates the device ID of BMC
(Baseboard Management Controller.
(View only)
BMC Firmware
Revision
–
Indicates BMC (Baseboard
Management Controller) firmware
revision number. (View only)
BMC Device Revision
–
Indicates BMC (Baseboard
Management Controller) device revision
number. (View only)
PIA Revision
–
Indicates the revision of PIA (Platform
Information Area). (View only)
SDR Revision
–
Indicates the revision of SDR (Sensor
Data Record). (View only)
Primary HSBP Revision
–
Indicates primary HSBP (Hot-Swap
Backplane) revision number. (View
only)
Summary of Contents for Express 5800/120Lg
Page 1: ... S e r v i c e G u i d e EXPRESS5800 120Lg ...
Page 2: ......
Page 4: ......
Page 10: ......
Page 73: ...Disassembly and Reassembly 4 7 Figure 4 2 Installing the Left Hand Side Access Panel ...
Page 132: ......
Page 161: ...6 Illustrated Parts Breakdown Exploded View Field Replaceable Units ...
Page 168: ......
Page 169: ...A Specifications System Specifications ...
Page 179: ...C IRQ and I O Port Addresses Interrupt Requests PIRQ and PCI Device ...
Page 188: ......
Page 198: ......
Page 203: ...xx ...
Page 204: ... 456 01673 000 ...