ioLogik E2200 Series
Using ioAdmin
3-39
ioLogik E2242 Network I/O Server Configuration
==============================================
[System Information]
Date: 2010/04/07
Time: 06:10:56
Firmware: V3.4 Build10032218
Click&Go=2.1
MOS= V3.2.34
[1. Model]
----------
MOD_TYPE=E2242 - Active Ethernet I/O Server (12DIO + 4AI)
MOD_LOC=
MOD_NAME=
[2. I/O Configurations]
-----------------------
DI00=1,(Counter),
DI00_PWN=0,(Stop), DI00_SAFE=0,(Stop),
DI00_FILTER=1,(0.500ms),
DI00_TRIGGER=0,(L2H),
DI01=0,(DI),
DI01_FILTER=100,(50.000ms)
DI02=0,(DI),
DI02_FILTER=100,(50.000ms)
DI03=0,(DI),
DI03_FILTER=100,(50.000ms)
DI04=0,(DI),
DI04_FILTER=100,(50.000ms)
DI05=0,(DI),
DI05_FILTER=100,(50.000ms)
DO06=1,(Pulse),
DO06_PWN=0,(Stop),
DO06_SAFE=0,(Stop),
DO06_LOW=2,(5.000ms),
DO06_HIGH=2,(5.000ms),
DO06_CNT=2000
DO07=1,(Pulse),
DO07_PWN=1,(Start),
DO07_SAFE=1,(Start),
DO07_LOW=1,(5.000ms),
DO07_HIGH=1,(5.000ms),
DO07_CNT=0
DO08=0,(DO),
DO08_PWN=0,(Off), DO08_SAFE=0,(Off)
DO09=0,(DO),
DO09_PWN=0,(Off), DO09_SAFE=0,(Off)
DO10=0,(DO),
DO10_PWN=0,(Off), DO10_SAFE=0,(Off)
DO11=0,(DO),
DO11_PWN=0,(Off), DO11_SAFE=0,(Off)
AI00=5,(4-20mA),
AI00_EN=1
AI01=3,(+/-10V),
AI01_EN=1
AI02=3,(+/-10V),
AI02_EN=1
AI03=3,(+/-10V),
AI03_EN=1
AI00_SCALEN=0, AI00_ACTmin=0.000,
AI00_ACTmax=0.000,
AI00_SCALmin=0.000,
AI00_SCALmax=0.000,
AI00_UNIT=V
AI01_SCALEN=0, AI01_ACTmin=0.000,
AI01_ACTmax=0.000,
AI01_SCALmin=0.000,
AI01_SCALmax=0.000,
AI01_UNIT=V
AI02_SCALEN=0, AI02_ACTmin=0.000,
AI02_ACTmax=0.000,
AI02_SCALmin=0.000,
AI02_SCALmax=0.000,
AI02_UNIT=V
AI03_SCALEN=0, AI03_ACTmin=0.000,
AI03_ACTmax=0.000,
AI03_SCALmin=0.000,
AI03_SCALmax=0.000,
AI03_UNIT=V
AI00_SCALE2_M=1.000,
AI00_SCALE2_D=0.000,
AI01_SCALE2_M=1.000,
AI01_SCALE2_D=0.000,
AI02_SCALE2_M=1.000,
AI02_SCALE2_D=0.000,
AI03_SCALE2_M=1.000,
AI03_SCALE2_D=0.000,
Import System Config
Select this command to load a configuration for the selected ioLogik from a configuration text file. You will need
to be logged in as an administrator to use this command. The new configuration will not take effect until the
ioLogik has been restarted. This command can be used to restore a configuration after loading the factory
defaults, or to duplicate a configuration to multiple ioLogik units.
Summary of Contents for ioLogik E2210
Page 138: ...ioLogik E2200 Series Cable Wiring D 4 Digital Output Sink Type...
Page 139: ...ioLogik E2200 Series Cable Wiring D 5 RTD Input Wiring Structure 2 wire 3 wire...
Page 140: ...ioLogik E2200 Series Cable Wiring D 6 Thermocouple Input Wiring Structure 2 wire...
Page 144: ...ioLogik E2200 Series Input and Output Terminal E 4 ioLogik E2262 I O left to right...