Part 9: Review on Replacement of Optional Peripheral Equipment
9 - 28
6. EMC FILTER
POINT
Recommended EMC filters for the MR-J2S series are different from those for the
MR-J4 series.
6.1 MR-J2S-Series EMC Filter (200 V/100 V class)
It is recommended that one of the following filters be used to comply with the EN EMC Directive. Some EMC
filters have large in leakage current.
Combination with the servo amplifier
Servo amplifier
Recommended filter
Mass [kg]
Model Leakage
current
[mA]
MR-J2S-10_ to MR-J2S-100_
MR-J2S-10_1 to MR-J2S-40_1
SF1252 38
0.75
MR-J2S-200_/MR-J2S-350_ SF1253
57
1.37
MR-J2S-500_ (Note)
HF3040A-TM
1.5
5.5
MR-J2S-700_ (Note)
HF3050A-TM
1.5
6.7
MR-J2S-11K_ (Note)
HF3060A-TMA
3.0
10.0
MR-J2S-15K_ (Note)
HF3080A-TMA
3.0
13.0
MR-J2S-22K_ (Note)
HF3100A-TMA
3.0
14.5
MR-J2S-30K_/MR-J2S-37K_ (Note)
HF3200A-TMA
3.0
23.5
Note. Soshin Electric. A surge protector is separately required to use any of these EMC filters.
(Refer to EMC Installation Guidelines.)
LINE
LOAD
NFB
MC
Servo amplifier
1
2
3
4
5
6
E
MC
NFB
1
2
3
1 2 3
ENC filter
(SF1252 • SF1253)
(Note 1)
Power
supply
(Note 2)
L
1
L
2
L
3
L
1
'
L
2
'
L
3
'
L
1
L
2
L
3
L
11
L
21
(Note 1)
Power
supply
ENC filter
(Soshin Electric)
Servo amplifier
L
1
L
2
L
3
L
11
L
21
Surge protector 1
(RAV-7818XZ-2)
(Okaya Electric Industries)
Surge protector 2
(RAV-7818XZ-4)
(Okaya Electric Industries)
Note1. With 1-phase 230 V AC, connect the power supply to L1 and L2, and leave L3 open.
L3 is not provided for 1-phase 100 V AC to 120 V AC.
2. When the power supply has an earth wire, connect it to this terminal
.
6.1.1 Dimensions
LABEL
LI
NE
LO
AD
168.0
L1'
L2'
L3'
L1
L2
L3
149.5
LINE
LOAD
140.0
15
6.
0
16.0
42.0
8.5
φ6.0
SF1252
LA
BE
L
LINE
LOAD
168.0
L1'
L2'
L3'
L1
L2
L3
209.5
LINE
LOAD
14
0.
0
156.0
23.0
49.0
8.5
φ6.0
SF1253
[Unit: mm]
(Input side)
(Output side)
(Input
side)
(Output
side)
Summary of Contents for MELSERVO-J2-Super Series
Page 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Page 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Page 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Page 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Page 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Page 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Page 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Page 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Page 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Page 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Page 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...