Part 7: Common Reference Material
7 - 56
MR-J2S-_A_ MR-J4-_A_
Conversion rule
No.
Name
Type Target No. Type Target
44
Input signal selection 3
Hex
_ _ _ X
PD11 Hex
_ _ XX
When the setting value of No. 0 is _ _ _ 0, _ _ _
2, or _ _ _ 4 or when the value of No. 42 is other
than _ _ _ 1, this parameter will be converted.
The setting value will be converted as shown in
Table 1 (as input) in Section 2.3.5 (6).
However, a setting value other than those in
Table 1 (as input) in (6) in 2.3.5 will be
converted to _ _03. (RES)
When conversion of I/O signal assignment is
enabled, this parameter will be converted
according to the control signal connection of the
renewal tool.
When conversion of I/O signal assignment is not
enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or later.
_ _ X _
XX _ _
When the setting value of No. 0 is _ _ _ 0, _ _ _
2, or _ _ _ 4 or when the value of No. 42 is other
than _ _ _ 1, this parameter will be converted.
The setting value will be converted as shown in
Table 2 (as input) in Section 2.3.5 (6).
However, a setting value other than those in
Table 2 (as input) in Section 2.3.5 (6) will be
converted to 03_ _. (RES)
When conversion of I/O signal assignment is
enabled, this parameter will be converted
according to the control signal connection of the
renewal tool.
When conversion of I/O signal assignment is not
enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or later.
Hex
_ X _ _ PD12
Hex
_ _ XX
When the setting value of No. 0 is _ _ _ 0, _ _ _
2, or _ _ _ 4 or when the value of No. 42 is other
than _ _ _ 1, this parameter will be converted.
The setting value will be converted as shown in
Table 3 (as input) in Section 2.3.5 (6).
However, a setting value other than those in
Table 3 (as input) in (6) in 2.3.5 will be
converted to _ _03. (RES)
When conversion of I/O signal assignment is
enabled, this parameter will be converted
according to the control signal connection of the
renewal tool.
When conversion of I/O signal assignment is not
enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or later.
Hex: hexadecimal parameter; Dec: decimal parameter
Summary of Contents for MELSERVO-J2-Super Series
Page 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Page 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Page 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Page 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Page 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Page 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Page 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Page 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Page 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Page 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Page 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...