8. MDS-B-SP/SPH, SPJ2 Spindle Parameters
8.1 MDS-B-SP/SPH, SPJ2 Spindle Base Specifications Parameters
II - 210
#
Items
Details
Setting range (Unit)
3021 sori
Orientation
rotation
speed
Set the spindle orientation rotation speed.
Set the rotation speed for when the spindle
rotates at the constant rotation speed.
0 to 32767 (r/min)
3022 sgear
Encoder gear ratio
Set the gear ratio of the spindle to the
encoder.
0: 1/1
1: 1/2
2: 1/4
3: 1/8
3023 smini
Minimum
rotation
speed
Set the minimum rotation speed of the
spindle.
If an S command instructs the rotation
speed below this setting, the spindle rotates
at the minimum rotation speed set by this
parameter.
0 to 32767 (r/min)
3024
(PR)
sout
Spindle connection Set the type of the spindle to be connected.
0: No connection with the spindle
1: Serial connection (bus)
2 to 5: Analog output
0 to 5
3025 enc-on
Spindle encoder
Set connection information of the spindle
encoder.
0: No connection
1: Spindle connection (Spindle encoder
connection check function valid.)
2: Serial connection of encoder
0 to 2
3026 cs_ori
Selection
of
winding in
orientation mode
0: Perform orientation using the winding
selected when the orientation
command is issued.
1: Use winding L whenever the orientation
command is issued.
0/1
3027 cs_syn Selection
of
winding in spindle
synchronous mode
0: The winding H/L is selected by the
actual spindle motor rotation speed
(calculated from commanded rotation
speed) when spindle synchronous
control starts. (The winding is not
switched during synchronous control.
The control is carried out with the
winding selected at start.)
If the actual spindle motor rotation
speed is less than SP020, the winding L
is selected, and if more than the value,
the winding H is selected.
1: Use winding H whenever the spindle
synchronous command is issued.
0/1
3028 sprcmm
L system tap cycle
spindle forward run/
reverse run M
command
Set the M code of the spindle forward
run/reverse run command.
High-order three digits:
The spindle
forward run
command's M
code is set.
Low-order three digits:
The spindle
reverse run
command's M
code is set.
0 to 999999