(9) M01 AUX OPER. ALM
Alarm
information
Details Cause
Remedy
0101
No operation mode The operation mode is not
designated, or the operation
mode was changed during axis
movement.
• Correctly designate the operation
mode.
0103
Feedrate 0
The operation parameter's
feedrate setting is zero.
The operation parameter
feedrate setting is zero.
Or, the override is valid, and the
override value is zero.
• Set a value other than zero in the
feedrate setting or override value.
0160
Station No.
designation illegal.
Starting not
possible.
A station No. exceeding the No.
of indexed divisions was
designated.
• Correctly designate the station
No.
0161
Reference point
return incomplete.
Starting not
possible.
Automatic/manual operation was
started before reference point
return was executed with the
incremental system.
• Execute the reference point
return.
0162
In initializing
reference point.
Starting not
possible.
The start signal was input while
initializing the absolute position
reference point.
• Complete the absolute position
reference point initialization.
0163
In absolute
position alarm.
Starting not
possible.
The start signal was input during
an absolute position alarm.
• Initialize the absolute position
reference point and then fix the
absolute position coordinates.
0164
In random
positioning mode.
Manual operation
not possible.
The manual operation mode was
started during the random
positioning mode.
• Turn the random positioning
mode OFF before switching to
the manual operation mode.
0165
Uneven indexing
station No. illegal.
Starting not
possible.
The commanded station No. was
higher than 9 or the number of
indexing stations during uneven
indexing.
• Check the commanded station
No. and the parameter “#100
station” setting.