8. Spindle Parameters
8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
II - 246
No. Items
Details
Setting
range
Standard
setting
3243
(PR)
SP043 TRNG
Synchro-
nous
tapping,
spindle
synchro-
nous
detector
range
This parameter is used to set the synchronous
tapping or spindle synchronous detector range.
Set "0" for this parameter.
0 to 7
0
3244
(PR)
SP044 TRANS NC
communi-
cation
frequency
Set a frequency of data communication with
NC.
0 to 32767 Standard:
0
Special:
1028
3245 SP045 CSNT
Dual
cushion
timer
Set the cycle to add the increment values in the
dual cushion process.
When this setting value is increased, the dual
cushion will increase, and the changes in the
speed during acceleration/deceleration will
become gradual.
0 to 1000
(ms)
0
3246
(PR)
SP046 CSN2
Speed
command
dual
cushion
For an acceleration/deceleration time constant
defined in SP019 (CSN1) , this parameter is
used to provide smooth movement only at the
start of acceleration/deceleration.
As the value of this parameter is smaller, it
moves smoother but the
acceleration/deceleration time becomes longer.
To make this parameter invalid, set "0".
0 to 1000
0
3247
(PR)
SP047 SDTR
Speed
detection
reset value
Set the reset hysteresis width for a speed
detection set value defined in SP020 (SDTS).
0 to 1000
(r/min)
30
3247
(PR)
SP047 SDTR
Speed
detection
reset value
Set the reset hysteresis width for a speed
detection set value defined in SP020 (SDTS).
0 to 1000
(r/min)
30
3248
(PR)
SP048 SUT
Speed
reach
range
Set the speed deviation rate with respect to the
commanded speed for output of the speed
reach signal.
0 to 100
(%)
15
3249 SP049 TLM2 Torque
limit 2
Set the torque limit rate for the torque limit
signal 010.
1 to 120
(%)
20
3250 SP050 TLM3
Torque
limit 3
Set the torque limit rate for the torque limit
signal 011.
1 to 120
(%)
30
3251 SP051 TLM4
Torque
limit 4
Set the torque limit rate for the torque limit
signal 100.
1 to 120
(%)
40
3252 SP052 TLM5
Torque
limit 5
Set the torque limit rate for the torque limit
signal 101.
1 to 120
(%)
50
3253 SP053 TLM6
Torque
limit 6
Set the torque limit rate for the torque limit
signal 110.
1 to 120
(%)
60
3254 SP054 TLM7
Torque
limit 7
Set the torque limit rate for the torque limit
signal 111.
1 to 120
(%)
70