(PR)
SP033 SFNC1 Spindle
function 1
Set the spindle function 1 in bit units.
0000 to
FFFF
HEX setting
0000
F E D
C
B A 9 8
poff hzs
ront
pycal pychg
7 6 5 4 3 2 1 0
pyst
pyoff
sftk
dflt 1a2m
(Note)
Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
0
1a2m
1 amplifier
2 motor function: Invalid
1 amplifier
2 motor function: Valid
1
dflt
Default motor: Main
Default motor: Sub
2
sftk
SF-TK card invalid
SF-TK card valid
3
4
5
6 pyoff
7 pyst
8 pychg
This is used by Mitsubishi.
Set to "0" unless particularly designated.
9
pycal
(Conventional
specifications)
High-speed rate
deceleration method
valid for minimum
excitation rate
A
B
This is used by Mitsubishi.
Set to "0" unless particularly designated.
C
ront
Normal ready ON
High-speed ready ON
D
This is used by Mitsubishi.
Set to "0" unless particularly designated.
E
hzs
Gate OFF by high-cycle
zero speed invalid
Gate OFF by high-cycle
zero speed valid
F
poff
Contactor hold at NC
power OFF invalid
Contactor hold at NC
power OFF valid
(Note)
When SPH is used, bit 0 and bit 1 will be invalid.