7. Servo Parameters
7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
II - 174
No. Items
Details
Setting
range
2224 SV024
INP
In-position
detection
width
Set the in-position detection width.
Set the accuracy required for the machine.
The lower the setting is, the higher the positioning
accuracy gets, however, the cycle time (setting time)
becomes longer. The standard setting is “50”.
0 to 32767
(µm)
2225
(PR)
SV025
MTYP
Motor/
Detector
type
F E D C B A 9 8
pen ent
7 6 5 4 3 2 1 0
mtyp
bit Explanation
0
Set the motor type.
1
Set-
ting
0x 1x
2x
3x 4x
5x
6x 7x
2 x0
HA40N
HA50L
HA53L
3 x1
HA80N
HA100L
HA103L
4 x2
HA100N
HA200L
HA203L
5 x3
HA200N
HA300L
HA303L
6 x4
HA300N
HA500L
HA503L
7
mtyp
x5
HA700N
x6
HA900N
x7
HA-LH11K2
x8
HA-LH15K2
x9
xA
HA150L
HA153L
xB
xC
xD
xE
xF
Set-
ting
8x 9x Ax
Bx
Cx Dx Ex Fx
x0
HA43N
HC52
HC53
x1
HA83N
HC102
HC103 HC103R
x2
HA103N
HC152
HC153 HC153R
x3
HA203N
HC202
HC203 HC203R
x4
HA303N
HC352
HC353 HC353R
x5
HA703N
HC452
HC453 HC503R
x6
HC702
HC703
x7
HC902
x8
x9
xA
HA93N
xB
xC HA053(N)
xD HA13(N)
xE
HA23N
xF
HA33N
(To be continued to the next page)