7. Servo Parameters
7.1 MDS-B-SVJ2
II - 128
No. Items
Details
Setting
range
2261 SV061
DA1NO
D/A output
channel 1
data No.
2262 SV062
DA2NO
D/A output
channel 2
data No.
Input the data number you wish to output to D/A
output channel.
0 to 102
2263 SV063
DA1MPY
D/A output
channel 1
output scale
2264 SV064
DA2MPY
D/A output
channel 2
output scale
When "0" is set, output is done with the standard
output unit.
Set other than "0" when you wish to change the unit.
Set the scale with a 1/256 unit. When "256" is set,
the output unit will be the same as the standard
output unit.
-32768 to
32767
(Unit: 1/256)
2265 SV065
Not used. Set to "0".
0
Summary of Contents for MELDAS 60 Series
Page 1: ......
Page 2: ......
Page 4: ......
Page 6: ......
Page 10: ......
Page 13: ...I EXPLANATION OF ALARMS ...
Page 14: ......
Page 95: ...II EXPLANATION OF PARAMETERS ...
Page 96: ......
Page 443: ......