7. Servo Parameters
7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
II - 151
No. Items
Details
Setting
range
2233 SV033
SSF2
Servo
function
selection 2
F E D C B A 9 8
dos
hvx
svx
7 6 5 4 3 2 1 0
nfd2 nf3 nfd1 zck
bit
Meaning when "0" is set
Meaning when "1" is set
0 zck Z phase check valid (Alarm 42)
Z phase check invalid
1
Set the filter depth for Notch filter 1 (SV038).
2
Value
000
001
010
011
100 101 110
111
3
nfd1
Depth
(dB)
Infntly
deep
-18.1 -12.0
-8.5
-6.0 -4.1 -2.5
-1.2
Deep
Å
Æ
Shallow
4 nf3 Notch filter 3 stop
Notch filter 3 start (1125Hz)
5
Set the operation frequency of Notch filter 2 (SV046).
6
Value
000
001
010
011
100 101 110
111
7
nfd2
Depth
(dB)
Infntly
deep
-18.1 -12.0
-8.5
-6.0 -4.1 -2.5
-1.2
Deep
Å
Æ
Shallow
8 svx
Set the performance mode of the servo control.
(Only for MDS-C1-Vx)
9 hvx
00: By current loop gain
01: MDS-B-Vx compatible mode selected
10: High gain mode selected
11: High gain mode selected
A
B
C
Digital signal output selection
D
0
: MP scale absolute position detection, offset demand
signal output
E
1
: Specified speed signal output
F
dos
2 to F : Setting prohibited
(Note) Set to "0" for bits with no particular description.