2. Machining Parameters
2.1 Process Parameters
II - 9
<Deep hole drilling cycle>
#
Item
Contents
Setup range (unit)
8083 G83S modeM
(for M system only)
Set the M command code for changing to the small
diameter deep hole drilling cycle mode.
1 to 99999999
8084 G83S Clearanse
(for M system only)
Set the clearance amount for the G83 small
diameter deep hole drilling cycle.
0 to 999.999 (mm)
8085 G83S Forward F
(for M system only)
Set the feedrate from the R point to the cutting start
position in the G83 small diameter deep hole drilling
cycle.
0 to 99999 (mm/min)
8086 G83S Back F
(for M system only)
Set the speed for returning from the hole base
during the G83 small diameter deep hole drilling
cycle.
0 to 99999 (mm/min)
<SSS control>
#
Item
Contents
Setup range (unit)
8090 SSS
ON
(for M system only)
Set whether to validate SSS control with G05
P10000.
0: Invalid
1: Valid
0/1
8091 StdLength
(for M system only)
Adjust the maximum value of the range for
recognizing the shape.
To eliminate the effect of steps or errors, etc., set a
large value. To enable sufficient deceleration, set a
small value.
If "0.000" is set, the standard value (1.000mm) will
be applied.
0 to 100.000 (mm)
8092 ClampCoeff
(for M system only)
Adjust the clamp speed at the curved section
configured of fine segments.
Coefficient =
setting value
1 to 100
8093 StepLeng
(for M system only)
Set the width of the step at which the speed is not to
be decelerated. (Approximately the same as the
CAM path difference [Tolerance].)
If 0 is set, the standard value (5µm) will be applied.
If a minus value is set, the speed will decelerate at
all minute steps.
-0.001 to 0.100 (mm)
8094 DccWaitAdd
(for M system only)
Set the time to wait for deceleration when the speed
FB does not drop to the clamp speed.
0 to 100 (ms)
8095 Tolerance
(for M system only)
Set the tolerable error when the error between the
command path and tool path is large.
The error will decrease when a small value is set,
but the machining time will increase.
If "0.000" is set, the error will not be adjusted.
0 to 100.000 (mm)
Summary of Contents for MELDAS 60 Series
Page 1: ......
Page 2: ......
Page 4: ......
Page 6: ......
Page 10: ......
Page 13: ...I EXPLANATION OF ALARMS ...
Page 14: ......
Page 95: ...II EXPLANATION OF PARAMETERS ...
Page 96: ......
Page 443: ......