2. Operation Messages on Setting And Display Unit
2.1 Operation Errors
I - 49
Error No.
Error message
Details
E05 NOT
ACCEPTABLE
×
• The PLC timer cannot be set from the screen when the program
is valid. (When machine parameter bit selection #6449 bit 1 is set
to 1.)
• The PLC counter cannot be set from the screen when the
program is valid. (When machine parameter bit selection #6449
bit 0 is set to 1.)
• The tool registration data setting is prohibited. (When special
relay E71 is valid by the PLC.)
• Setting from the tool life management screen is prohibited.
• Absolute position setting screen's #1 "ORIGIN" and #2 "ZERO"
cannot be set when #0 "INIT SET" is invalid.
• The total of axes set in #1001 SYS_ON‚ #1002 axisno is illegal.
Set so that the total No. of axes is within the specifications range
for the target model.
• #1037 cmdtyp is not within the setting range.
• The INPUT key was pressed to perform search for the program
that is in background edit status on the word edit screen.
• The menu keys (Replace and Insert) on the word edit screen
were manipulated when a running program is displayed (PDISP
signal: ON).
• An attempt was made to set MDI data in an MDI setting lock state
(the MDI setting lock parameter is specified with 0 and a
non-MDI mode is valid).
• Language data in display selection status was entered. Change
the display selection status once before entering the data.
(#1043 lang)
• When the manual value command protection (#1228 aux12/bit7)
function is valid, the first monitor screen was manipulated by
manual command operation (M, S, and T keys).
E06 NO
SPEC
×
• The menu key for a function not in the specifications was
pressed.
• A parameter not in the specifications was set.
• A language that was not added as an option was selected.
(#1043 lang)
• Set up parameter #1049 mmac_R was set to “1” when the
machine manufacturer macro option was not valid.
• Set up parameter #1060 SETUP was set to “20” when the
machine manufacturer macro option was not valid.
• Writing of the machine manufacturer macro program with the
PROGRAM COPY screen was attempted when the machine
manufacturer macro option was not valid.