7. Servo Parameters
7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
II - 191
Motor
HA
43N
HA
83N
HA
93N
HA
103N
HA
203N
HA
303N
HA
703N
Drive unit
capacity
05 10 20 35 45 70 90
SV001
PC1
- -
-
-
-
- -
SV002
PC2
- -
-
-
-
- -
SV003
PGN1
33 33
33
33
33
33 25
SV004
PGN2
0 0
0
0
0
0 0
SV005
VGN1
150 150
150
150
150
150 250
SV006
VGN2
0 0
0
0
0
0 0
SV007
VIL
0 0
0
0
0
0 0
SV008
VIA
1364 1364
1364
1364
1364
1364 1364
SV009
IQA
2048 2048
2048
2048
2048
2048 2048
SV010
IDA
2048 2048
2048
2048
2048
2048 2048
SV011
IQG
256 256
256
256
256
256 200
SV012
IDG
512 512
512
512
512
512 256
SV013
ILMT
500 500
500
500
500
500 500
SV014
ILMTsp
500 500
500
500
500
500 500
SV015
FFC
0 0
0
0
0
0 0
SV016
LMC1
0 0
0
0
0
0 0
SV017
SPEC
0000 0000
0000
0000
0000
0000 0000
SV018
PIT
- -
-
-
-
- -
SV019
RNG1
- -
-
-
-
- -
SV020
RNG2
- -
-
-
-
- -
SV021
OLT
60 60
60
60
60
60 60
SV022
OLL
150 150
150
150
150
150 150
SV023
OD1
6 6
6
6
6
6 6
SV024
INP
50 50
50
50
50
50 50
SV025
MTYP
xx80 xx81
xx8A
xx82
xx83
xx84 xx85
SV026
OD2
6 6
6
6
6
6 6
SV027
SSF1
4000 4000
4000
4000
4000
4000 4000
SV028
0 0
0
0
0
0 0
SV029
VCS
0 0
0
0
0
0 0
SV030
IVC
0 0
0
0
0
0 0
SV031
OVS1
0 0
0
0
0
0 0
SV032
TOF
0 0
0
0
0
0 0
Summary of Contents for MELDAS 60 Series