Appendix 5. Servo/Spindle Cable and Connector Specifications (MDS-D-SVJ3/SPJ3)
5.2 Cable Connection Diagram
231
5.2 Cable Connection Diagram
CAUTION
1. Take care not to mistake the connection when manufacturing the detector
cable. Failure to observe this could lead to faults, runaway or fire.
2. When manufacturing the cable, do not connect anything to pins which have
no description.
5.2.1 Servo Detector Cable
<CNV2E-8P, CNV2E-9P cable connection diagram>
1
2
9
7
8
3
4
PE
8
5
3
4
6
7
1
2
10
P5(+5V)
LG
BT
SD
SD*
RQ
RQ*
P5(+5V)
LG
CNT
BT
SD
SD*
RQ
RQ*
SHD
0.5mm
2
Case
grounding
0.2mm
2
0.2mm
2
0.2mm
2
Servomotor detector/
Ball screw side detector side connector
Plug: CM10-SP10S-M (Straight)
CM10-AP10S-M (Angle)
Contact: CM10-#22SC
Servo drive unit side connector
(3M)
Receptacle: 36210-0100PL
Shell kit: 36310-3200-008
(MOLEX)
Connector set: 54599-1019
<For 15m or less>
1
2
9
7
8
3
4
PE
8
5
3
4
6
7
1
2
10
P5(+5V)
LG
BT
SD
SD*
RQ
RQ*
P5(+5V)
LG
CNT
BT
SD
SD*
RQ
RQ*
SHD
0.5mm
2
Case
grounding
0.2mm
2
0.5mm
2
0.2mm
2
0.2mm
2
Servomotor detector/
Ball screw side detector side connector
Plug: CM10-SP10S-M (Straight)
CM10-AP10S-M (Angle)
Contact: CM10-#22SC
Servo drive unit side connector
(3M)
Receptacle: 36210-0100PL
Shell kit: 36310-3200-008
(MOLEX)
Connector set: 54599-1019
<For 15m to 30m>