Appendix 4. Servo/Spindle Cable and Connector Specifications (MDS-D/DH)
4.3 Main Circuit Cable Connection Diagram
216
4.3 Main Circuit Cable Connection Diagram
The methods for wiring to the main circuit are shown below.
4.3.1 DRSV1 cable, DRSV2 cable
These cables are used to connect the servo drive unit's TE1 terminal and HF(-H) / HP(-H) motor.
•
DRSV1 cable : This is the power line for the single-axis unit (MDS-D/DH-V1-) and dual-axis
integrated unit (MDS-D/DH-V2-) L axis.
•
DRSV2 cable : This is the power line for the dual-axis integrated unit (MDS-D/DH-V2-) M axis.
<DRSV1/DRSV2 cable connection diagram>
1: U
2: V
3: W
4:
A
B
C
D
Drive unit side
Motor side
CAUTION
1. The main circuit cable must be manufactured by the user.
2. Refer to the section "5. Selection of peripheral devices" in MDS-D/DH
Series Specifications Manual when selecting the wire material.
3. Lay out the terminal block on the drive unit side as shown in "Appendix 1.
Outline dimension drawing" in MDS-D/DH Series Specifications Manual.
4. Refer to "Appendix 1-1 Servomotor outline dimension drawings" in
MDS-D/DH Series Specifications Manual for details on the servomotor's
connectors and terminal block.