6. Connections of Control Unit
6.6 Connecting with Optical Communication Servo Drive Unit
62
(Note 3)
Loop the excessive cable with twice or more than the minimum bending radius.
Recommended clamp material
CKN-13SP
KITAGAWA INDUSTRIES
Optical communication cable
(section with reinforced sheath):
Bending radius: 50mm or more
Optical communication cable
(section without reinforced sheath):
Bending radius: 25mm or more
Control unit
<Related items>
Cable drawing: "Appendix 2 (G380 Cable, G395 Cable, G396 Cable)"
Connector pin assignment: "Appendix 3 (OPT1 connector)"
(2) Criteria for optical cable selection
<G396 Cable>
Wire material
: Optical communication cable POF type (Core: Plastic)
Application
: Use when wiring a cable of 10m or less inside the panel.
Min. bending radius :
Cable
Minimum bending radius
2-core parallel cord
30mm or more
<G395 Cable>
Wire material
: Optical communication cable POF type (Core: Plastic)
Application
: Use when wiring a cable of 10m or less outside the panel.
Min. bending radius :
Cable
Minimum bending radius
2-core cable (section with reinforced sheath)
50mm or more
2-core cable (section without reinforced sheath)
30mm or more
<G380 Cable>
Wire material
: Optical communication cable PCF type (Core: Glass)
Application
: Use when the cable length is 10m or more to 20m or less.
Min. bending radius :
Cable
Minimum bending radius
2-core cable (section with reinforced sheath)
50mm or more
2-core cable (section without reinforced sheath)
25mm or more