6. Connections of Control Unit
6.2 Connecting with Power Supply
59
(2) Specifications of PD25/PD27 power supply
Item PD25
PD27
Input power voltage 200V to 230VAC
+10%-15%
50/60Hz ± 1Hz
200V to 480VAC
+10%-15%
50/60Hz ± 3Hz
Output current
3A
8A
Dimension
130mm x 65mm x 230mm
170mm x 65mm x 230mm
Mass 1.5kg
2.5kg
Output holding time 300ms
300ms
(Note)
PD25/PD27 cannot be turned ON immediately after it is turned OFF. Wait at least 2 seconds, and
then turn the power ON.
6.3 Connecting with Operation Panel I/O Unit
Connect operation panel I/O unit to the connector OPI.
MITSUBISHI
OPI
G013 cable
NC control unit
Operation panel
I/O unit
OPI
(Note)
When not using operation panel I/O unit, place terminator E-TM on the OPI connector. If nothing is
connected to the OPI connector, emergency stop will be applied.
(Even if operation panel I/O unit is connected, if the unit's power is OFF, emergency stop will be
applied.)