Appendix 3. Connectors
3.2 Connectors for Operation Panel I/O Unit
199
3.2.7 Ethernet Connector (LAN)
Name : LAN
8 1
<Cable side connector type>
Plug :
5-569550-3
Recommended manufacturer
: Tyco Electronics AMP
1
I
RD+
2
I
RD+
3
O
TD+
4
5
6
O
TD-
7
8
* Use a straight cable (G301) for
connection with the display unit.
3.2.8 24VDC Input Connector (DCIN)
Name : DCIN
1
3
1
I +24V
2
0V
3
FG
<Cable side connector type>
Connector :
2-178288-3
Contact :
1-175218-5
x3
Recommended manufacturer : Tyco Electronics AMP