8. Connections of I/O Interface
8.5 Connecting with Expansion I/O Card QY231
135
Machine output terminal
CFD83
1
18
50
33
<Cable side connector type>
Connector: MRP50M01
Contact: MRP-M102
Case: MR50W
Recommended manufacturer:
HONDA TSUSHIN KOGYO
CFD83
1
Y08 33
DC24V
2
Y0B
34
Y0A
3
Y0E 19
Y09 35 Y0D
4
Y01 20
Y0C 36 Y00
5
Y04 21
Y0F 37 Y03
6
Y07 22
Y02 38 Y06
7
Y1A 23
Y05 39 Y19
8
Y1D 24
Y18 40 Y1C
9
Y1F 25
Y1B 41 Y1E
10
Y12 26
Y10 42 Y11
11
Y15 27
Y13 43 Y14
12
Y28 28
Y16 44 Y17
13
Y2B 29
Y29 45 Y2A
14
Y2E 30
Y2C 46 Y2D
15
Y21 31
Y2F 47 Y20
16
Y24 32
Y22 48 Y23
17
Y26 49
Y25
18
0V(RG)
50 Y27
CS1
0
* This example shows CS1 set to "0".
Refer to "PLC Interface Manual" for details.
(3) Rotary switch
Set the address (station No.) assignment for two stations in DI/DO: 64/48 point units. Set using the CS1
rotary switch. The assignment address is changed with the rotary switch setting.
CS1
Setting Function
0
Remote I/O station 0, 1 station selection
1 Invalid
2
Remote I/O station 2, 3 station selection
3 Invalid
4
Remote I/O station 4, 5 station selection
5 Invalid
6
Remote I/O station 6, 7 station selection
7 Invalid
8~F Setting
prohibited
0
CS1
∗
The X
and Y
assignments are reference values. When actually making the assignment, add DI/DO
assignment No. to the head address assigned to each remote IO unit station No.
(4) Setting switches
Set the digital input sink type and source type changeover.
S1, S2
S3, S4
Function
ON
OFF
Source input selection
OFF
ON
Sink input selection