3. General Specifications (Environment Conditions)
3.3 Remote I/O Unit
13
3.3 Remote I/O Unit
Unit name
Remote I/O unit
Item
Type
FCUA-DX10
FCUA-DX11
FCUA-DX12
FCUA-DX14
During
operation
0 to 55°C
Ambient
temperature During
storage
-20 to 60°C
Long term
10 to 75% RH (with no dew condensation)
Ambient
humidity
Short term
10 to 95% RH (with no dew condensation)
(Note 1)
Vibration resistance
4.9m/s
2
or less (during operation)
Shock resistance
29.4m/s
2
or less (during operation)
General
specifi-
cations
Working atmosphere
No corrosive gases, dust
Input power voltage
24VDC
±
5% Ripple noise 200mV
(P-P)
Power capacity
24V 0.7A
(Note 2)
24V 1.5A
(Note 2)
24V
0.7A
(Note 2)
Required
Power
specifi-
cation
Instantaneous stop
tolerance time
—
Heating value (Max.)
25W
(Note 3)
30W
(Note 3)
30W
(Note 3)
Others
Mass
0.5kg 0.6kg 0.6kg 0.6kg
(Note 1)
The period is within one month.
(Note 2)
Amount consumed by control circuit
(Note 3)
Differs according to the number of machine input operation points and the load and number of
points connected to the machine output. The maximum value applies when all points are ON.
3.4 Servo / Spindle
Refer to the following manuals for details on the servo and spindle system.
MDS-D Series
Specification Manual
(IB-1500011)
MDS-DH Series
Specification Manual
(IB-1500003)
MDS-D-SVJ3/SPJ3 Series
Specification Manual
(IB-1500158)