8. Connections of I/O Interface
8.2 Connecting with Remote I/O Unit
102
8.2.6 Outline of Analog Signal Output Circuit
The analog signal output circuit can be used only for the FCUA-DX120/DX121/DX140/DX141.
Output circuit
DAC
R
R
A0
A0*
OV(RG)
220
Ω
Output conditions
Output voltage
0V to ±10V (±5%)
Resolution
12bit (±10V × n/4096)
(Note)
Load conditions
10k
Ω
load resistance
Output impedance
220
Ω
(Note)
n = (2
0
to 2
11
)