Appendix 1. EMC Installation Guidelines
1.6 EMC Countermeasure Parts
165
1.6.4 Selection of Stabilized Power Supply
Consider the following characteristics when selecting the stabilized power supply (prepared by machine
manufacturer).
Use a power supply that complies with CE Marking or that follows the safety standards given below.
Stabilized power supply selection items
Item
Standard
setting
Remarks
Voltage fluctuation
±5%
±5% or less of 24VDC output
Ripple noise
120mV (max.)
Output
Spike noise
500mV (max.)
Output current
-
Refer to the maximum current consumption of the unit in use
and calculate.
Output holding time
20ms (min.)
Instantaneous power failure time (AC side)
Standards
Safety Standards
: UL1950, CSA C22.2 No. 234 approved, IEC950 compliant
Noise Terminal Voltage
: FCC Class A, VCCI-Class A
High Harmonics Current Restrictions : IEC61000-3-2