Technical Information
98
G 600/G 800
A program can only be restarted after the fault has been addressed and the fault code has
been deleted.
The following faults are possible:
NTC sensor or its connections short- or open-circuited
Control module fault
Heater circuit open-circuited
6.8.4.4.2
Program Interruption and Intake/Drain LED Flashes
Program selection is possible.
The electronic has registered a fault during program operation. This can be checked via
Service Mode 2
.
The following faults are possible:
Water intake or drainage
Flow meter B3/4 - Heater pressure switch B1/10
Overflow level switch B1/2
6.8.5
G 681, G 881 Novo Stella, G 886 Novo Stella Plus
(G 681/G 881 shown)
Programming Flow Chart
Enter
Programming Mode
To access:
Program index
Water hardness settings
Extended drying 14 minutes
Extended water intake
Buzzer (EGPL 552 only)
Enter
Service Mode 1
To access:
Manual step mode
Component test program
Enter
Service Mode 2
To access:
Fault codes
Operating hours
Increased water temperature selection
Water softener (with/without)
Extended water intake
Interim rinses
Extended drying 45 minutes
Table 6-26:
G 681, G 881 Novo Stella, G 886 Novo Stella Plus Programming Flow Chart
6.8.5.1 Programming
Mode
1. To access the
programming mode
,
close the door and turn the program
selector switch to
Stop
. Turn the dishwasher off.
2. Press and hold the
Delay Start
and
Start
buttons while turning the dishwasher
on. A blinking
Salt
light indicates successful accessing of the
programming