Technical Information
47
G 600/G 800
5.0
Service and Maintenance
5.1
Locking Plate Adjustment
1. Loosen the two screws (Figure 5-1, Item 1).
2. Adjust the locking plate in the direction of the arrow as required.
3. Tighten the screws.
Figure 5-1:
Locking Plate
5.2
Door Seal Replacement
1. Open the door.
2. Remove the old seal.
3. Clean the groove around the cabinet.
Note:
Coating the seal with water may simplify installation.
4. Press the new seal in the groove; see Figure 5-2, Item 1. The seal lip should
point inwards.
5. Then press the middle of the new seal into the groove under the locking plate;
see Figure 5-2, Item 2. At the same time, press the seal into the corners.
6. Now press the remaining seal parts into the groove, working upwards in the
direction of the arrows; see Figure 5-2, Item 3.