Technical Information
93
G 600/G 800
6.8.3.3.2
Deleting Stored Fault Codes
Access
Programming Mode
and turn the dishwasher off.
6.8.3.3.3 Program
Index
1. Access
Service Mode 2
.
2. Turn the program selector switch to the 2 o’clock position. The
Top solo
light flashes.
3. Press
the
Top solo
button once, then turn the program selector switch slowly clockwise
until the
Top solo
light lights up. The program selector switch position will determine the
corresponding program index, as shown in Table 6-18 below.
4. Turn the dishwasher off.
Program selector position Program index
Electronic version
1 o’clock
P0
EPLG 542/544
2 o’clock
P1
For future modifications
3 o’clock
P3
For future modifications
Table 6-18:
G 811, G 851, G 851 Plus, G 856, G 856 Plus
Program Indices
6.8.4
G 680, G 880
Programming Flow Chart
Enter
Programming Mode
To access:
Water hardness
Drying Plus (EPLZ 501 only)
Temperature reduction (EPLZ 501 only)
Enter
Service Mode 1
To access:
Switching step check
Test program
Enter
Service Mode 2
To access:
Fault indication
Program index
Temperature increase
Softener
Flow meter
Dishwasher width setting
Increased water quantity (EPLZ 520 only)
Table 6-19:
G 680,
G 880 Programming Flow Chart
Note:
Electronics EPLZ 501 and EPLZ 520 differ from each other in housing, plug
configuration and software. The designation can be checked in
Service Mode 2
.
EPLZ 520 is marked with the program index “P3”
or higher.
6.8.4.1 Programming
Mode
1.
S
witch the appliance off at the on/off switch, close the door and turn the program
selector switch to
Stop
.