Technical Information
71
G 600/G 800
5.45
Turbidity Sensor Removal
1. Remove as much water as possible from the sump.
2. Lay the dishwasher on its back.
3. Remove the drip pan. See Section 5.29.
4. Disconnect the electrical connection to the turbidity sensor.
5. Loosen the hose clips and remove the hoses from the sensor.
Re-installation note:
Ensure that the turbidity sensor is installed with the arrow (on the bottom of the
sensor) in the direction of the water flow.
5.46
Fully Integrated (Vi) Control Panel Removal
1. Open the door.
2. Hold the control panel (Figure 5-38, Item 9) while removing the interior screws
(Figure 5-38, Item 10).
3. Lift the control panel from the appliance.
Figure 5-38:
Fully Integrated (Vi) Control Panel
5.47
Novotronic and Touchtronic Control Panel Removal
Note:
On Novotronic dishwashers, the program knob (Figure 5-39, Item 1) must be
removed before the fascia (Figure 5-39, Item 4) and control panel (Figure 5-39,
Item 3). Pull the knob outward to remove it from the appliance.
1. Open the door.
2. Hold the fascia (Figure 5-39, Item 4) and control panel (Figure 5-39, Item 3) while
removing the interior screws (Figure 5-39, Item 14).
1
Screws
2
Mounting bracket
3
Electronic
4
Door closure screw
5
Wiring harness
6
Electronic
7
Screws
8
Screws
9
Control panel
10
Panel screws