Parameter
number
Unit of
measurement
Standard
value
Minimum
value
Maximum
value
Description
36
Sec.
0
0
100
54
Sec.
10
10
120
110
-
100
0
100
Oven light activation time, set to 0 sec. = light always on.
E.g.: Set to 20 sec. = light automatically goes out after
20 seconds, therefore by setting a value other than zero
the lighting is timed, permitting savings in energy and on
the component.
Duration of TIME OUT: after a time of 10 seconds you
automatically exit the function "programming" phase,
the displays show the time and actual temperature.
From the moment the operator believes he is
sufficiently familiar with the the functions of the
appliance, this TIME OUT can be lowered so as to "exit"
the programming / viewing phase more quickly.
Volume Set to 100 = maximum volume. To lower the
volume, set values under 100, the volume will decrease
proportionally down to a minimum set by the
manufacturer.
Connection with printer (HACCP):
with core probe cooking,
prints out the values every 5
°
C at the food.
Connection with printer (HACCP):
with time cooking, prints out the values every
5 minutes.