40
24 • SELF-DIAGNOSIS AND FAULT IDENTIFICATION
900-----rev00
BOILER HIGH - B o i l e r s a f e t y t h e r m o s t a t t r i p s ,
switch off the oven immediately and contact a
technician or authorized service agent.
NO DRAINAGE - Indicates failure to drain the water
from the steam generator. It is possible to use the
appliance all the same, remembering that the water
has not regenerated.
Press key 15 to bypass the fault temporarily.
If the fault appears during the “BOILER WASH”
program it will stop the appliance, contact a
technician or authorized service agent.
DESCALER - It appears when switching off the
appliance and signals the need to activate the
steam generator descaling cycle. See chapter 22.
To bypass the signal temporarily, press key 15.
DOOR OPEN - It appears when the door is open
and signals that the door microswitch fails to close
the contact.
Check that the door is closed;
if the signal reappears contact a technician or
authorized service agent.
CLEAN ERR - Error during the automatic wash
phase.
It appears when the oven temperature exceeds
110 °C during the MAN, SOFT or HARD clean
phase.
T h i s f a u l t w i l l s t o p t h e a p p l i a n c e , c o n t a c t a
technician or authorized service agent.
CLIMA
2 5
2 5 0 2 ,3 4
M A N U A L
B O I L E R H I G H
CLIMA
2 5
2 5 0 2 ,3 4
M A N U A L
N O D R A I N A G E
CLIMA
2 5
2 5 0 2 ,3 4
M A N U A L
D E S C A L I N G
CLIMA
2 5
2 5 0 2 ,3 4
M A N U A L
D O O R O P E N
CLIMA
2 5
2 5 0 2 ,3 4
M A N U A L
C L E A N E R R