The main fault warning messages are:
MESSAGES
CHAMBER ERR - Message on the display 9. Oven
temperature probe faulty, switch off the oven
immediately and contact a technician or authorized
service agent.
NO WATER - This symbol lights up when there is no
water reaching the appliance, in which case check
that the shutoff valve is open and that there is water
still coming from the main. If there is no supply from
the main, inform the water company or agency. If there
is no problem with the main, contact a technician or
authorized service agent. In the meantime, the oven can
still be used in convection mode, after pressing key 15
to bypass the error signal.
MOTOR HIGH - The device preventing thermal
overload of the motor has cut in. Switch off the oven
immediately and contact a technician or authorized
service agent.
CHAMBER HIGH - The oven safety thermostat has
cut in. Switch off the oven immediately and contact a
technician or authorized service agent.
Q U E N C H I N G E R R O R - V a p o u r c o n d e n s a t i o n
temperature probe faulty. The condenser is in
operation continuously, but the oven can still be used
under close observation in convection and steam
mode but not in combination mode (increased water
consumption), until the arrival of a service technician.
HOT - An abnormally high temperature rise has
registered in the compartment housing electrical
components. The oven can still be used under close
observation, until the arrival of a service technician.
TOO HOT - An excessive temperature rise registering
in the electrical components compartment could result
in damage to components. Switch off the oven
immediately and contact a technician or authorized
service agent.
24 • SELF-DIAGNOSIS AND FAULT IDENTIFICATION
CLIMA
2 5
2 5 0 2 ,3 4
M A N U A L
C H A M B E R E R R
CLIMA
2 5
2 5 0 2 ,3 4
M A N U A L
N O WAT E R
CLIMA
2 5
2 5 0 2 ,3 4
M A N U A L
M O T O R H I G H
CLIMA
2 5
2 5 0 2 ,3 4
M A N U A L
C H A M B E R H I G H
CLIMA
2 5
2 5 0 2 ,3 4
M A N U A L
Q U E N C H I N G E R R O R
CLIMA
2 5
2 5 0 2 ,3 4
M A N U A L
H O T
CLIMA
2 5
2 5 0 2 ,3 4
M A N U A L
T O O H O T