GASOLINE STERNDRIVE INSTALLATION MANUAL
90-860172011
Page 115 of 137
3.0L Single Point Drain
CAUTION
Ensure bilge pump is operating before beginning procedures. Excess water in bilge
can damage engine or cause boat to sink.
CAUTION
Allow engine to cool down before disconnecting blue drain hoses. Engine water
temperature can exceed 160
°
F (71
°
C).
CAUTION
Do not operate engine with blue drain hoses disconnected. Hot water can discharge
violently.
IMPORTANT: Do NOT start or operate engine at any point in this procedure.
1. Turn on bilge pump.
2. Push quick connect fitting release buttons and remove blue drain hoses from the
bracket.
76242
a
b
a -
Quick Connect Fitting Release button
b -
Blue Drain Hoses
3. Pull T-handle until the hose guide is in contact with the quick connect fittings.
76243
b
a
a -
T-Handle
b -
Hose Guide