Error Messages
6-5
11817 Rev. A
6. Error Messages
Illegal Color Sequence
In the Color Menu you must have at least one valid thread number in the Color Change
Sequence. Valid numbers are 1 to 10 and zero. You cannot exit from the Color Menu without cor-
recting the sequence.
Loading Design Try Again
Means that the design has not completed reloading during a Power Fail Recovery. Wait a few sec-
onds and try again.
Machine Running
You have tried to activate a menu that is not permitted while the machine is sewing. Stop the
machine and try again.
Missed Headup
The Z axis controller missed a Head Up signal. The machine waits for another 150 degrees of rota-
tion; and if the signal still hasn't been seen, stops sewing. This error halts the CPU; you must turn
the power OFF, then ON, then perform a Power Fail Recovery. If this happens frequently call your
Melco service representative for help.
Motor Command Buffer Full
The motor command buffer is full. You may have created more Move commands or Head Timing
commands than the buffer can hold. To clear the MC buffer, turn the power OFF, then back ON. If
cycling the power does not clear the screen message, there may be an error in the CPU. Reconfig-
ure your peripheral. If this still does not clear the message, call your Melco service representative
for assistance.
No Designs Found
This means you are trying to enter the Design menu and there are no designs loaded in memory.
Either no designs have been sent from the computer or they have been automatically or manually
deleted. The AutoDelete option may be ON at the computer.
No Design Qued
You have attempted to do a Power Fail Recovery, a Goto Stitch, or a Goto Color, but there is no
design in the run buffer. You must queue a design and try again.
No Free Memory
Tried to load a design from a floppy disk, but the design memory is full. Delete a design from
memory and try again (make sure the design you delete will free enough space for the new
design).
Summary of Contents for EMT 10/4
Page 52: ...2 28 Quick Start Operation Manual for the EMT 10T 10 4 and 10 4T Melco Embroidery Systems ...
Page 108: ...6 10 Error Messages Operation Manual for the EMT 10T 10 4 and 10 4T Melco Embroidery Systems ...
Page 126: ...INDEX Operation Manual for the EMT 10T 10 4 and 10 4T ...
Page 127: ...Quick Ref erence Guide for the EMT 10T 10 4 and 10 4T 11817 Revision A ...